Recommendation 1 of the 102nd CIPM (2013)
Updates to the list of standard frequencies
The International Committee for Weights and Measures (CIPM),
considering that
- a common list of “Recommended values of standard frequencies for applications including the practical realization of the metre and secondary representations of the second” has been established,
- the CCL-CCTF Frequency Standards Working Group (FSWG) has reviewed several candidates for inclusion into the list,
recommends the following changes to the list of “Recommended values of standard frequencies for applications including the practical realization of the metre and secondary representations of the second”:
- that the following transition frequency be added to the list:
- the unperturbed optical transition 6s2 1S0 – 6s 6p 3P0 of the 199 Hg neutral atom with a frequency of
1 128 575 290 808 162 Hz and an estimated relative standard uncertainty of1.7 × 10–14;
- the unperturbed optical transition 6s2 1S0 – 6s 6p 3P0 of the 199 Hg neutral atom with a frequency of
- that the following transition frequencies be updated in the list:
- the unperturbed optical transition 4s 2S1/2 – 3d 2D5/2 of the 40Ca+ ion with a frequency of
411 042 129 776 395 Hz and an estimated relative standard uncertainty of1.5 × 10–14; - the unperturbed optical transition 1S – 2S of the 1H neutral atom with a frequency of
1 233 030 706 593 518 Hz and an estimated relative standard uncertainty of1.2 × 10–14;
- the unperturbed optical transition 4s 2S1/2 – 3d 2D5/2 of the 40Ca+ ion with a frequency of
Note: This frequency corresponds to half of the energy difference between the 1S and 2S states;
- that the following transition frequencies be updated in the list and endorsed as secondary representations of the second:
- the unperturbed optical transition 6s 2S1/2 – 4f 136s2 2F7/2 of the 171Yb+ ion (octupole) with a frequency of
642 121 496 772 645.6 Hz and an estimated relative standard uncertainty of1.3 × 10–15; - the unperturbed optical transition 6s2 1S0 – 6s 6p 3P0 of the 171Yb neutral atom with a frequency of
518 295 836 590 865.0 Hz and an estimated relative standard uncertainty of2.7 × 10–15;
- the unperturbed optical transition 6s 2S1/2 – 4f 136s2 2F7/2 of the 171Yb+ ion (octupole) with a frequency of
- that the following transition frequency be added to the list and as a secondary representation of the second:
- the unperturbed optical transition 3s2 1S0 – 3s 3p 3P0 of the 27Al+ ion with a frequency of
1 121 015 393 207 857.3 Hz and an estimated relative standard uncertainty of 1.9 × 10–15;
- the unperturbed optical transition 3s2 1S0 – 3s 3p 3P0 of the 27Al+ ion with a frequency of
- that the following transition frequencies be updated in the list and as secondary representations of the second:
- the unperturbed optical transition 5d 106s 2S1/2 – 5d 96s2 2D5/2 of the 199Hg+ ion with a frequency of
1 064 721 609 899 145.3 Hz and an estimated relative standard uncertainty of1.9 × 10–15; - the unperturbed optical transition 6s 2S1/2 (F = 0, mF = 0) – 5d 2D3/2 (F = 2, mF = 0) of the 171Yb+ ion (quadrupole) with a frequency of
688 358 979 309 307.1 Hz and an estimated relative standard uncertainty of 3 × 10–15; - the unperturbed optical transition 5s 2S1/2 – 4d 2D5/2 of the 88Sr+ ion with a frequency of
444 779 044 095 485.3 Hz and an estimated relative standard uncertainty of4.0 × 10–15; - the unperturbed optical transition 5s2 1S0 – 5s5p 3P0 of the 87Sr neutral atom with a frequency of
429 228 004 229 873.4 Hz and an estimated relative standard uncertainty of1 × 10–15;
- the unperturbed optical transition 5d 106s 2S1/2 – 5d 96s2 2D5/2 of the 199Hg+ ion with a frequency of
- that the following transition frequency be updated as a secondary representation of the second:
- the unperturbed ground - state hyperfine transition of 87Rb with a frequency of
6 834 682 610.904 312 Hz and an estimated relative standard uncertainty of1.3 × 10–15.
- the unperturbed ground - state hyperfine transition of 87Rb with a frequency of
Note: The value of the estimated standard uncertainty is assumed to correspond to a confidence level of
DOI : 10.59161/CIPM2013REC1E