To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Argentina, CNEA (National Commission of Atomic Energy)
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 100 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 1.3 %
4π(PC)-γ coincidence efficiency tracer counting, balance
Cs-137, acid solution
Reference standard : 4π(PC)-γ coincidence efficiency tracer counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2093
CMC ID : SIM-RI-AR-00000H0L-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 1000 Bq/g to 2.00E5 Bq/g
Relative expanded uncertainty 0.4 %
Liquid-scintillation counting (TDCR), balance
Y-90, glass ampoule
Reference standard : Liquid-scintillation counting (TDCR), weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2180
CMC ID : SIM-RI-AR-00000H17-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 300 Bq/g to 3.00E6 Bq/g
Relative expanded uncertainty 0.9 %
4π(PPC)-γ coincidence counting, balance
Ir-192, acid solution
Reference standard : 4π(PPC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2107
CMC ID : SIM-RI-AR-00000H0T-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 300 Bq/g to 3.00E6 Bq/g
Relative expanded uncertainty 0.8 %
4π(PC)-γ coincidence counting, balance
Zn-65, acid solution
Reference standard : 4π(PPC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2105
CMC ID : SIM-RI-AR-00000H0R-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 300 Bq/g to 3.00E6 Bq/g
Relative expanded uncertainty 3.4 %
4π(PPC)-γ coincidence counting, balance
Eu-152, acid solution
Reference standard : 4π(PPC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2098
CMC ID : SIM-RI-AR-00000H0P-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 100 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 3 %
4π(PC)-γ coincidence counting, balance
Se-75, acid solution
Reference standard : 4π(PC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2094
CMC ID : SIM-RI-AR-00000H0M-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 3.8 %
Germanium spectrometer
Se-75, point source, active diameter < 5 mm
Reference standard : 4π(PC)β-γ coincidence counting system
Source of traceability : CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2020
CMC ID : SIM-RI-AR-00000H1E-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 3.3 %
Germanium spectrometer
Y-88, point source, active diameter < 5 mm
Reference standard : Gamma ray spectrometer
Source of traceability : CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2022
CMC ID : SIM-RI-AR-00000H1G-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 3 %
Germanium spectrometer
Mn-54, point source, active diameter < 5 mm
Reference standard : Gamma ray spectrometer
Source of traceability : LNE-LNHB
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2017
CMC ID : SIM-RI-AR-00000H1B-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 1.9 %
Germanium spectrometer
Cs-137, point source, active diameter < 5 mm
Reference standard : 4π(PC)-γ coincidence efficiency tracer counting
Source of traceability : CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2027
CMC ID : SIM-RI-AR-00000H1L-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 2.5 %
Germanium spectrometer
Sn-113, point source, active diameter < 5 mm
Reference standard : Gamma ray spectrometer
Source of traceability : CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2024
CMC ID : SIM-RI-AR-00000H1I-1
 
Ionizing radiation
Activity , Solution, single-radionuclide source : 1.00E7 Bq to 4.00E10 Bq
Relative expanded uncertainty 4 %
Ionization chamber dose calibrator
Sm-153, 5 mL in LMR vials
Reference standard : Gamma ray spectrometer (efficiency curve)
Source of traceability : LNE-LNHB, CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2088
CMC ID : SIM-RI-AR-00000H0H-1
 
Ionizing radiation
Activity , Solution, single-radionuclide source : 1.00E7 Bq to 4.00E10 Bq
Relative expanded uncertainty 4 %
Ionization chamber dose calibrator
Ga-67, 5 mL in LMR vials
Reference standard : Gamma ray spectrometer (efficiency curve)
Source of traceability : LNE-LNHB, CNEA-LMR
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2084
CMC ID : SIM-RI-AR-00000H0D-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 3 %
Germanium spectrometer
Eu-154, point source, active diameter < 5 mm
Reference standard : Gamma ray spectrometer
Source of traceability : LNE-LNHB
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2029
CMC ID : SIM-RI-AR-00000H0B-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 0.1 Bq/g to 1.00E5 Bq/g
Relative expanded uncertainty 0.8 %
Liquid-scintillation counting (CIEMAT/NIST), balance
Tl-204, glass ampoule
Reference standard : Liquid-scintillation counting (CIEMAT/NIST), weight set
Source of traceability : NIST (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2104
CMC ID : SIM-RI-AR-00000H0Y-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 0.1 Bq/g to 1.00E5 Bq/g
Relative expanded uncertainty 1.9 %
Liquid-scintillation counting (CIEMAT/NIST), balance
P-32, glass ampoule
Reference standard : Liquid-scintillation counting (CIEMAT/NIST), weight set
Source of traceability : NIST (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2103
CMC ID : SIM-RI-AR-00000H0X-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 100 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 1 %
Defined solid-angle (Silicon ion implanted detector)
Pu-238, point source
Reference standard : Defined-solid-angle counter with alpha detector
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2099
CMC ID : SIM-RI-AR-00000H0V-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 300 Bq/g to 3.00E6 Bq/g
Relative expanded uncertainty 0.6 %
4π(PPC)-γ coincidence counting, balance
Co-60, acid solution
Reference standard : 4π(PPC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2102
CMC ID : SIM-RI-AR-00000H0Q-1
 
Ionizing radiation
Activity per unit mass , Solution, single-radionuclide source : 100 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 5.1 %
4π(PC)-γ coincidence counting, balance
Ho-166m, acid solution
Reference standard : 4π(PC)-γ coincidence counting, weight set
Source of traceability : CNEA-LMR (Bq), SCS-METAS (g)
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2106
CMC ID : SIM-RI-AR-00000H0S-1
 
Ionizing radiation
Activity , Solid, single-radionuclide source : 100 Bq to 2.00E5 Bq
Relative expanded uncertainty 4 %
Germanium spectrometer
Am-241, point source, active diameter < 5 mm
Reference standard : Gamma ray spectrometer
Source of traceability : LNE-LNHB
Approved on 10 October 2013
Institute service identifier : SIM-RAD-CNEA-2030
CMC ID : SIM-RI-AR-00000H0C-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.