Results for: Bosnia and Herzegovina
				Filters
				
					CMC Quick search Filters close;
				 
				
					
					
						
							CMC Area
							
							
							
							To filter, either use the tick boxes or click on the underscored item
						 
						
						
						
						
						
						
					 
			 
			
				
				
				
					In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
					Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
				
					Bosnia and Herzegovina, IMBIH (Institute of Metrology of Bosnia and Herzegovina)
					
						
    
        
        
        
            
                
                    
                        | Matrix or material | Analyte or component | Dissemination range of measurement capability | Range of certified values in reference materials | 
                    
                        | Mass fraction in mg/g | Absolute expanded uncertainty in mg/g | Mass fraction in | Absolute expanded uncertainty in | 
                    
                        | yellow gold jewellery alloys | gold | 375 to 750 | 0.5 |  |  | 
                    
                
             
            
                
                
                
                
                - 
                    Mechanism for measurement service delivery :
                    Reference measurement service
                
- 
                    Primary reference material NIST-SRM 685-R is used for the purpose of reference value asignement when organizing PT schemes by IMBiH. Gravimetry method according ISO 11426. Determination of gold in gold jewellery alloys. Cupelation method (fire assay)
                
- 
                    Approved on
                    08 July 2015
                
- 
                    Institute service identifier :  LH-1
                
- 
                    CMC ID :
                    EURAMET-QM-BA-000000SX-1
                      
 
     
 
					 
					
						
    
        
            
                AC current ,
				 AC current up to 100 A: meters
                :
                1.00E-4 A to 10 A
            
            
                AC ammeter, multimeter
            
            
                Relative expanded uncertainty
                :
                0.36 mA/A to 3.5 mA/A
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"50 Hz","col_3":"1 kHz","col_4":"5 kHz","col_5":"10 kHz"},"row_2":{"col_1":"100 µA","col_2":"0.50","col_3":"0.50","col_4":"0.50","col_5":"0.55"},"row_3":{"col_1":"190 µA","col_2":"0.45","col_3":"0.45","col_4":"0.45","col_5":"0.45"},"row_4":{"col_1":"0.2 mA","col_2":"1.30","col_3":"1.30","col_4":"1.30","col_5":"1.30"},"row_5":{"col_1":"1 mA","col_2":"0.45","col_3":"0.45","col_4":"0.45","col_5":"0.45"},"row_6":{"col_1":"1.9 mA","col_2":"0.36","col_3":"0.36","col_4":"0.36","col_5":"0.36"},"row_7":{"col_1":"2 mA","col_2":"1.30","col_3":"1.30","col_4":"1.30","col_5":"1.30"},"row_8":{"col_1":"10 mA","col_2":"0.45","col_3":"0.45","col_4":"0.45","col_5":"0.45"},"row_9":{"col_1":"19 mA","col_2":"0.36","col_3":"0.36","col_4":"0.36","col_5":"0.36"},"row_10":{"col_1":"20 mA","col_2":"1.30","col_3":"1.30","col_4":"1.30","col_5":"1.30"},"row_11":{"col_1":"100 mA","col_2":"0.45","col_3":"0.45","col_4":"0.45","col_5":"0.45"},"row_12":{"col_1":"190 mA","col_2":"0.36","col_3":"0.36","col_4":"0.36","col_5":"0.36"},"row_13":{"col_1":"0.2 A","col_2":"1.60","col_3":"1.60","col_4":"1.70","col_5":"1.70"},"row_14":{"col_1":"1 A","col_2":"0.80","col_3":"0.80","col_4":"0.90","col_5":"0.90"},"row_15":{"col_1":"1.9 A","col_2":"0.71","col_3":"0.71","col_4":"0.82","col_5":"0.82"},"row_16":{"col_1":"2 A","col_2":"1.80","col_3":"1.80","col_4":"3.50","col_5":"3.50"},"row_17":{"col_1":"10 A","col_2":"1.00","col_3":"1.00","col_4":"2.70","col_5":"2.70"}}
                    
                    
                 
             
            
            
                Direct comparison with a reference standard
            
            
            
                Frequency : 50 Hz to 10 kHz
            
            
            
                Approved on 11 May 2017
            
            
                Institute service identifier :  IMBiH/15
            
            
                CMC ID :
                EURAMET-EM-BA-00000CA3-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC voltage (up to 1100 V) ,
				 DC voltage meters: intermediate values
                :
                0.01 V to 1000 V
            
            
                DC voltmeter, multimeter
            
            
                Relative expanded uncertainty
                :
                4 µV/V to 1.7E1 µV/V
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"Expanded uncertainty (µV/V)"},"row_2":{"col_1":"10 mV","col_2":"17"},"row_3":{"col_1":"20 mV","col_2":"10"},"row_4":{"col_1":"50 mV","col_2":"6.5"},"row_5":{"col_1":"100 mV","col_2":"4.5"},"row_6":{"col_1":"190 mV","col_2":"4.5"},"row_7":{"col_1":"0.2 V","col_2":"4.5"},"row_8":{"col_1":"0.5 V","col_2":"4.5"},"row_9":{"col_1":"1 V","col_2":"4"},"row_10":{"col_1":"1.9 V","col_2":"4"},"row_11":{"col_1":"5 V","col_2":"4"},"row_12":{"col_1":"10 V","col_2":"4"},"row_13":{"col_1":"15 V","col_2":"4"},"row_14":{"col_1":"19 V","col_2":"4"},"row_15":{"col_1":"20 V","col_2":"6.5"},"row_16":{"col_1":"50 V","col_2":"5.5"},"row_17":{"col_1":"100 V","col_2":"5.5"},"row_18":{"col_1":"190 V","col_2":"6.5"},"row_19":{"col_1":"200 V","col_2":"8.5"},"row_20":{"col_1":"500 V","col_2":"6.5"},"row_21":{"col_1":"900 V","col_2":"5.5"},"row_22":{"col_1":"1000 V","col_2":"5.5"}}
                    
                    
                 
             
            
            
                Comparison with reference digital multimeter
            
            
            
            
            
                Approved on 11 May 2017
            
            
                Institute service identifier :  IMBiH/4
            
            
                CMC ID :
                EURAMET-EM-BA-00000CA7-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC voltage (up to 1100 V) ,
				 DC voltage sources: low values
                :
                0.01 V to 10 V
            
            
                DC voltage source, multifunction calibrator
            
            
                Relative expanded uncertainty
                :
                4 µV/V to 1.7E1 µV/V
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"Expanded uncertainty (µV/V)"},"row_2":{"col_1":"10 mV","col_2":"17"},"row_3":{"col_1":"20 mV","col_2":"10"},"row_4":{"col_1":"50 mV","col_2":"6.5"},"row_5":{"col_1":"100 mV","col_2":"4.5"},"row_6":{"col_1":"190 mV","col_2":"4.5"},"row_7":{"col_1":"0.2 V","col_2":"4.5"},"row_8":{"col_1":"0.5 V","col_2":"4.5"},"row_9":{"col_1":"1 V","col_2":"4"},"row_10":{"col_1":"1.9 V","col_2":"4"},"row_11":{"col_1":"5 V","col_2":"4"},"row_12":{"col_1":"10 V","col_2":"4"}}
                    
                    
                 
             
            
            
                Comparison with reference digital multimeter
            
            
            
            
            
                Approved on 11 May 2017
            
            
                Institute service identifier :  IMBiH/2
            
            
                CMC ID :
                EURAMET-EM-BA-00000CA5-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC current (up to 100 A) ,
				 DC current meters: intermediate values
                :
                1.00E-4 A to 10 A
            
            
                DC current meter,  multimeter
            
            
                Relative expanded uncertainty
                :
                2.7E1 µA/A to 6.3E2 µA/A
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"Expanded uncertainty  (µA/A)"},"row_2":{"col_1":"190 µA","col_2":"33"},"row_3":{"col_1":"0.2 mA","col_2":"41"},"row_4":{"col_1":"0.5 mA","col_2":"35"},"row_5":{"col_1":"1 mA","col_2":"29"},"row_6":{"col_1":"1.9 mA","col_2":"27"},"row_7":{"col_1":"2 mA","col_2":"38"},"row_8":{"col_1":"5 mA","col_2":"35"},"row_9":{"col_1":"10 mA","col_2":"29"},"row_10":{"col_1":"19 mA","col_2":"27"},"row_11":{"col_1":"20 mA","col_2":"79"},"row_12":{"col_1":"50 mA","col_2":"60"},"row_13":{"col_1":"100 mA","col_2":"53"},"row_14":{"col_1":"190 mA","col_2":"48"},"row_15":{"col_1":"0.2 A","col_2":"335"},"row_16":{"col_1":"0.5 A","col_2":"280"},"row_17":{"col_1":"1 A","col_2":"220"},"row_18":{"col_1":"1.9 A","col_2":"205"},"row_19":{"col_1":"2 A","col_2":"625"},"row_20":{"col_1":"5 A","col_2":"520"},"row_21":{"col_1":"10 A","col_2":"450"}}
                    
                    
                 
             
            
            
                Direct comparison with multifunction calibrator
            
            
            
            
            
                Approved on 11 May 2017
            
            
            
                CMC ID :
                EURAMET-EM-BA-00000C9W-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC current (up to 100 A) ,
				 DC current sources: low values
                :
                10 µA to 100 µA
            
            
                DC current generator, multifunction calibrator
            
            
                Relative expanded uncertainty
                :
                1.4E1 µA/A to 5.0E1 µA/A
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"Expanded uncertainty  (µA/A)"},"row_2":{"col_1":"10 µA","col_2":"50"},"row_3":{"col_1":"20 µA","col_2":"29"},"row_4":{"col_1":"50 µA","col_2":"18.5"},"row_5":{"col_1":"100 µA","col_2":"13.5"}}
                    
                    
                 
             
            
            
                Direct comparison with reference digital multimeter
            
            
            
            
            
                Approved on 11 May 2017
            
            
            
                CMC ID :
                EURAMET-EM-BA-00000CAF-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC voltage (up to 1100 V) ,
				 DC voltage sources: single values
                :
                10 V
            
            
                Solid state voltage standard
            
            
                Relative expanded uncertainty
                :
                1 µV/V
            
            
            
            
                Direct comparison with a bank of solid state standards
            
            
            
            
            
                Approved on 11 May 2017
            
            
                Institute service identifier :  IMBiH/1
            
            
                CMC ID :
                EURAMET-EM-BA-00000CA4-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                DC resistance ,
				 DC resistance standards and sources: intermediate values
                :
                1 Ω to 1.00E5 Ω
            
            
                Fixed resistor
            
            
                Relative expanded uncertainty
                :
                0.65 µΩ/Ω
            
            
                Uncertainty table
                
                    {"row_1":{"col_1":"","col_2":"Expanded uncertainty  (µΩ/Ω)"},"row_2":{"col_1":"1 Ω to 10 Ω","col_2":"0.65"},"row_3":{"col_1":"10 Ω to 10 kΩ","col_2":"0.65"},"row_4":{"col_1":"10 kΩ to 100 kΩ","col_2":"0.65"}}
                    
                    
                 
             
            
            
                DC current comparator
            
            
            
            
            
                Approved on 11 May 2017
            
            
            
                CMC ID :
                EURAMET-EM-BA-00000CAA-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Mass ,
				 Mass
                :
                1 mg to 100 mg
            
            
                Mass standard
            
            
                Absolute expanded uncertainty
                :
                0.7 µg to 2 µg
            
            
            
            
                Comparison in air
            
            
            
            
                Uncertainty scales with measurand level. The volume of the mass standards is known.
            
            
                Approved on 20 July 2015
            
            
            
                CMC ID :
                EURAMET-M-BA-00000D3H-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Pressure ,
				 Absolute pressure
                :
                1.00E4 Pa to 3.50E5 Pa
            
            
                Pressure balance
            
            
                Absolute expanded uncertainty
                
                
            
            
            
                0.3 Pa+3.0E-05p     p pressure in Pa
The uncertainty is expressed in Pa
             
            
                Gas medium
            
            
            
            
                Uncertainty values range from 0.60 Pa to 11 Pa.
            
            
                Approved on 10 February 2019
            
            
            
                CMC ID :
                EURAMET-M-BA-00000D3P-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Items for disseminating ITS-90 and PLTS 2000 ,
				 Temperature
                :
                -40 °C to 4 °C
            
            
                IPRT
            
            
                Absolute expanded uncertainty
                :
                9 mK
            
            
            
            
                Calibration by comparison at one temperature
            
            
            
                Stirred liquid bath : ethanol
            
            
                Uncertainty at the calibration point. Effect of hysteresis added to CMC budget.
            
            
                Approved on 20 February 2019
            
            
            
                CMC ID :
                EURAMET-T-BA-00000DE7-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Items for disseminating ITS-90 and PLTS 2000 ,
				 Temperature
                :
                4 °C to 70 °C
            
            
                SPRT
            
            
                Absolute expanded uncertainty
                :
                7 mK
            
            
            
            
                Calibration by comparison at one temperature
            
            
            
                Stirred liquid bath : water
            
            
                Uncertainty at the calibration point.
            
            
                Approved on 07 September 2016
            
            
            
                CMC ID :
                EURAMET-T-BA-00000DE5-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Items for disseminating ITS-90 and PLTS 2000 ,
				 Temperature
                :
                4 °C to 70 °C
            
            
                Temperature sensors with display unit
            
            
                Absolute expanded uncertainty
                :
                7 mK
            
            
            
            
                Calibration by comparison at one temperature
            
            
            
                Stirred liquid bath : water
            
            
                Uncertainty at the calibration point.
            
            
                Approved on 07 September 2016
            
            
            
                CMC ID :
                EURAMET-T-BA-00000DEE-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Frequency ,
				 Frequency
                :
                1.00E-3 Hz to 1.30E9 Hz
            
            
                General frequency source
            
            
                Absolute expanded uncertainty
                
                
            
            
            
                (2.0E-10)*f, f in Hz     The uncertainty is expressed in Hz
             
            
                Direct frequency measurement
            
            
            
                Averaging interval : N=1000
            
            
                Input square wave signal. DUT effects not included in uncertainty calculation.
            
            
                Approved on 10 June 2019
            
            
                Institute service identifier :  IMBIH/TF_2.2.1
            
            
                CMC ID :
                EURAMET-TF-BA-00000F73-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Time interval ,
				 Time interval
                :
                3.30E-9 s to 100 s
            
            
                Period source
            
            
                Absolute expanded uncertainty
                :
                0.6 ns
            
            
            
            
                Time interval counter
            
            
            
                Slewing rate : 0.5 V/ns
            
            
            
                Approved on 10 June 2019
            
            
                Institute service identifier :  IMBIH/TF_3.1.1
            
            
                CMC ID :
                EURAMET-TF-BA-00000F75-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Time interval ,
				 Time interval
                :
                1.00E-9 s to 1 s
            
            
                Delay source
            
            
                Absolute expanded uncertainty
                :
                0.6 ns
            
            
            
            
                Time interval counter
            
            
            
                Slewing rate : 0.5 V/ns
            
            
            
                Approved on 29 August 2016
            
            
                Institute service identifier :  IMBIH/TF_3.2.4
            
            
                CMC ID :
                EURAMET-TF-BA-00000F79-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Time interval ,
				 Time interval
                :
                1.00E-10 s to 1.00E-6 s
            
            
                Rise/fall time meter
            
            
                Absolute expanded uncertainty
                :
                4.4E-11 s to 5.8E-10 s
            
            
            
            
                Rise/fall time source
            
            
            
                Amplitude : - 5 V to +5 V
            
            
                DUT effects not included in uncertainty calculation.
            
            
                Approved on 10 June 2019
            
            
                Institute service identifier :  IMBIH/TF_3.4.1
            
            
                CMC ID :
                EURAMET-TF-BA-00000F7A-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Time interval ,
				 Time interval
                :
                1 s to 8.64E4 s
            
            
                Time difference meter
            
            
                Absolute expanded uncertainty
                :
                2.9E1 ms
            
            
            
            
                Totalize method
            
            
            
                Timebase error : 5.0E-13 s/s
            
            
                Including DUT's effect and operator response time.
            
            
                Approved on 10 June 2019
            
            
                Institute service identifier :  IMBIH/TF_3.4.3b
            
            
                CMC ID :
                EURAMET-TF-BA-00000F7C-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Fluid flow ,
				 Volume of liquid
                :
                1 L to 50 L
            
            
                Standard test measures and overflow pipettes
            
            
                Relative expanded uncertainty
                :
                2.0E-2 %
            
            
            
            
                Gravimetric
            
            
            
                Liquid : water
            
            
                Reference temperature : 20 °C
            
            
            
                Approved on 11 September 2019
            
            
                Institute service identifier :  LV-U.04
            
            
                CMC ID :
                EURAMET-M-BA-00000K0Y-1 
             
         
        
        
     
 
					 
					
						
    
        
            
                Frequency ,
				 Frequency
                :
                10 MHz
            
            
                Local frequency standard
            
            
                Relative expanded uncertainty
                :
                2.2E-13 Hz/Hz
            
            
            
            
                Phase time difference multiplication
            
            
            
                Averaging time: : 10 000 s
            
            
                Relative frequency difference: : < 1E-11
            
            
                For frequency stability measurement
            
            
                Approved on 31 August 2021
            
            
                Institute service identifier :  TF_2.1.1
            
            
                CMC ID :
                EURAMET-TF-BA-00000M77-1