Results for: Indonesia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
159 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Indonesia, SNSU-BSN (National Measurement Standard - National Standardization Agency of Indonesia)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 3.8 to 4.2 4.0E-3 3.8 to 4.2 1.8E-2
  • Mechanism for measurement service delivery : CRM and provision of value assignment for proficiency testing samples
  • Buffer name: Phthalate buffer.
    Measurement temperature of CRM : 25 °C
    The declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 23 October 2024
  • Institute service identifier : MC-1
  • CMC ID : APMP-QM-ID-000004XZ-4
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Relative expanded uncertainty in % Mass fraction in µg/kg Relative expanded uncertainty in %
drinking water, fresh water arsenic 1 to 100 4 to 1.0E1 8.38 to 23.8 4.3 to 5.5
  • Mechanism for measurement service delivery : CRM (IDNRM-MI-1-001 and IDNRM-MI-2-001) and provision of value assignment for proficiency testing samples
  • Approved on 15 August 2024
  • Institute service identifier : MI-1
  • CMC ID : APMP-QM-ID-00000PIQ-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in mg/kg Relative expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments benzoic acid 50 to 1000 5 to 8 493 7.3
  • Mechanism for measurement service delivery : CRM (IDNRM-MO-2-001) and provision of value assignment for proficiency testing samples
  • Approved on 22 July 2024
  • Institute service identifier : MO-2
  • CMC ID : APMP-QM-ID-000004Y0-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Relative expanded uncertainty in % Mass fraction in µg/kg Relative expanded uncertainty in %
drinking water, fresh water cadmium 0.1 to 50 5 to 8 3.06 to 4.46 6.5 to 7.5
  • Mechanism for measurement service delivery : CRM (IDNRM-MI-1-001 and IDNRM-MI-2-001) and provision of value assignment for proficiency testing samples
  • Approved on 15 August 2024
  • Institute service identifier : MI-1
  • CMC ID : APMP-QM-ID-00000PIR-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in % Amount-of-substance fraction in µmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 400 to 1000 1 400 to 1000 1
  • Mechanism for measurement service delivery : CRM and provision of value assignment for proficiency testing samples
  • Approved on 22 July 2024
  • Institute service identifier : MG-1
  • CMC ID : APMP-QM-ID-00000PJC-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount of substance fraction in mmol/mol Relative expanded uncertainty in % Amount of substance fraction in mmol/mol Relative expanded uncertainty in %
nitrogen carbon dioxide 1 to 500 0.65 1 to 500 0.65
  • Mechanism for measurement service delivery : CRM and provision of value assignment for proficiency testing samples
  • Approved on 22 July 2024
  • Institute service identifier : MG-1
  • CMC ID : APMP-QM-ID-00000PJA-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in mg/kg Relative expanded uncertainty in %
aqueous solution with nitric acid copper 100 to 1.00E4 0.5 to 1
  • Mechanism for measurement service delivery : Reference measurement service
  • Approved on 30 September 2024
  • Institute service identifier : MI-2
  • CMC ID : APMP-QM-ID-00000PIT-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in mg/kg Relative expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments methylparaben 50 to 500 6.6 to 9 90 7.8
  • Mechanism for measurement service delivery : CRM (IDNRM-MO-2-001) and provision of value assignment for proficiency testing samples
  • Approved on 08 October 2024
  • Institute service identifier : MO-2
  • CMC ID : APMP-QM-ID-000004Y1-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty in % Mass fraction in mg/kg Relative expanded uncertainty in %
water, aqueous-based beverages, aqueous-based condiments n-Butyl paraben 50 to 500 7 to 1.0E1 76.7 1.0E1
  • Mechanism for measurement service delivery : CRM (IDNRM-MO-2-001) and provision of value assignment for proficiency testing samples
  • Approved on 19 September 2024
  • Institute service identifier : MO-2
  • CMC ID : APMP-QM-ID-000004Y2-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Relative expanded uncertainty in % Mass fraction in µg/kg Relative expanded uncertainty in %
drinking water, fresh water nickel 1 to 100 5 to 1.0E1 60.7 5
  • Mechanism for measurement service delivery : CRM (IDNRM-MI-1-001) and provision of value assignment for proficiency testing samples
  • Approved on 15 August 2024
  • Institute service identifier : MI-1
  • CMC ID : APMP-QM-ID-00000PIS-1
     
Sound calibrators , Sound pressure level : 94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa)
Sound calibrator
Absolute expanded uncertainty : 0.1 dB
Calibrated measurement microphone
Frequency : 1 kHz
Microphone type : LS2P
Approved on 09 January 2012
Institute service identifier : A2
CMC ID : APMP-AUV-ID-00000D81-1
 
Linear vibration , Acceleration output (modulus) : 5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty : 1.3 %
ISO 16063-21
Frequency : 2500 Hz to 5000 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID : APMP-AUV-ID-00000D8F-1
 
Linear vibration , Acceleration output (modulus) : 5 m/s2 to 150 m/s2
Acceleration measuring instrument
Relative expanded uncertainty : 1.1 %
ISO 16063-21
Frequency : 63 Hz to 250 Hz
Approved on 06 June 2017
Institute service identifier : V4
CMC ID : APMP-AUV-ID-00000D8P-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 250 °C
Temperature sensor with display unit
Absolute expanded uncertainty : 2.0E-2 °C
Comparison using liquid bath
IPRT Sensors, Hysteresis not included in CMC
Approved on 10 November 2015
Institute service identifier : 1.3.4
CMC ID : APMP-T-ID-00000D8Z-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 6.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 63 Hz to 2.5 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID : APMP-AUV-ID-00000D82-1
 
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 7.0E-2 dB
IEC 61094-2:2009, ed. 2.0
Frequency : 3.15 kHz
Approved on 09 January 2012
Institute service identifier : A4
CMC ID : APMP-AUV-ID-00000D83-1
 
Mass , Mass : 20 kg
Mass standard
Absolute expanded uncertainty : 8 mg
Comparison in air
E2 Mass Standard (OIML-R-111)
Approved on 21 July 2009
Institute service identifier : 23
CMC ID : APMP-M-ID-00000D7U-1
 
Pressure , Gauge pressure: oil medium : 50 MPa to 100 MPa
Pressure balance
Absolute expanded uncertainty
2.8E-04P

P pressure in Mpa

The uncertainty is expressed in MPa

Direct comparison with pressure standard: crossfloat
Uncertainty values range from 14000 Pa to 28000 Pa
Approved on 23 March 2007
CMC ID : APMP-M-ID-00000D7Y-1
 
Pressure , Gauge pressure: oil medium : 0.5 MPa to 5 MPa
Pressure balance
Absolute expanded uncertainty
1E-04P

P pressure in Mpa

The uncertainty is expressed in MPa

Direct comparison with pressure standard: crossfloat
Uncertainty values range from 50 Pa to 500 Pa
Approved on 23 March 2007
CMC ID : APMP-M-ID-00000D7W-1
 
Time interval , Time interval : 1.00E-8 s to 1.00E-6 s
Rise/fall time source
Absolute expanded uncertainty : 2 ns
Time interval measurement
Slew rate : > 0.5 V/ns
Total time interval : 100 s, 10 measurements
Approved on 24 June 2019
Institute service identifier : SNSU-BSN/I.MF.3.02
CMC ID : APMP-TF-ID-00000FEK-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.