Results for: Mexico
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
764 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Chemical material
Chemical Analyte
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Mexico, CENAM (Centro Nacional de Metrologia)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 9.08 to 9.26 3.0E-3 to 1.0E-2 9.08 to 9.26 3.0E-3 to 1.0E-2
  • Mechanism for measurement service delivery : DMR 358
  • Temperature range for service: 15 °C to 37 °C, values given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2)
  • Approved on 31 March 2012
  • Institute service identifier : 630-Q024-001.p9
  • CMC ID : SIM-QM-MX-0000008P-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Absolute expanded uncertainty in S/m Electrolytic conductivity in S/m Absolute expanded uncertainty in S/m
aqueous solution 0.15 to 1.5 1.2E-3 to 1.2E-2 1.25 to 1.29 1.0E-2 to 1.1E-2
  • Mechanism for measurement service delivery : DMR-460
  • Reference value certified at 25 °C
  • Approved on 20 July 2020
  • Institute service identifier : 620-Q022-003.s
  • CMC ID : SIM-QM-MX-00000LQI-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in mS/m Absolute expanded uncertainty in mS/m Electrolytic conductivity in mS/m Absolute expanded uncertainty in mS/m
aqueous solution 15 to 150 4.8E-2 to 0.48 139 to 142.5 0.45 to 2
  • Mechanism for measurement service delivery : DMR-148
  • Reference value certified at 25 °C
  • Approved on 20 July 2020
  • Institute service identifier : 620-Q022-002.s
  • CMC ID : SIM-QM-MX-0000008T-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 3.99 to 4.03 1.0E-2 to 1.7E-2 3.99 to 4.03 1.0E-2 to 1.7E-2
  • Mechanism for measurement service delivery : CMR 283
  • Temperature range for service: 15 °C to 37 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 23 June 2021
  • Institute service identifier : 620-Q024- 001.p4
  • CMC ID : SIM-QM-MX-0000008N-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 6.8 to 7.5 3.2E-3 to 5.4E-3 6.8 to 7.5 4.0E-3 to 6.0E-3
  • Mechanism for measurement service delivery : CMR 206
  • Temperature range for service: 15 °C to 37 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 23 June 2021
  • Institute service identifier : 620-Q024-002.p7
  • CMC ID : SIM-QM-MX-0000008O-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in mS/m Absolute expanded uncertainty in mS/m Electrolytic conductivity in mS/m Absolute expanded uncertainty in mS/m
aqueous solution 1.5 to 15 2.6E-2 to 0.26 4.8 to 15.2 9.0E-2 to 0.4
  • Mechanism for measurement service delivery : DMR-297 and DMR-527
  • Reference value certified at 25 °C
  • Approved on 20 July 2020
  • Institute service identifier : 620-Q022-001.s and 620-Q022-004.s
  • CMC ID : SIM-QM-MX-0000008U-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 6.8 to 7.5 1.5E-2 6.8 to 7.5 1.5E-2
  • Mechanism for measurement service delivery : MRTC program (certification of a batch produced and latter distributed by an external manufacturer)
  • Temperature range for service and  given values: 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 23 June 2021
  • Institute service identifier : 620-Q024-006.s7
  • CMC ID : SIM-QM-MX-0000008S-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 3.8 to 4.2 1.5E-2 3.8 to 4.2 1.6E-2
  • Mechanism for measurement service delivery : MRTC program (certification of a batch produced and latter distributed by an external manufacturer)
  • Temperature range for service and given values: 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 16 July 2021
  • Institute service identifier : 620-Q024- 005.s4
  • CMC ID : SIM-QM-MX-0000008R-5
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous pH buffer solution 9.5 to 10.5 1.1E-2 9.5 to 10.5 1.3E-2
  • Mechanism for measurement service delivery : Primary measurement of carbonate CMR 324
  • Temperature range for service: 25 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 16 July 2021
  • Institute service identifier : 620-Q024-004.P10
  • CMC ID : SIM-QM-MX-0000008Q-5
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/g Relative expanded uncertainty in % Mass fraction in mg/g Relative expanded uncertainty in %
Multi-component ethanol/water solution 1-butanol 1 to 5 3 to 1.3 2 to 2.5 3 to 1.3
  • Mechanism for measurement service delivery : Analytical measurement and MRC DMR 380
  • Reference value assignment of VOC to PT and CRMs
  • Approved on 20 July 2020
  • Institute service identifier : 630-Q021-027
  • CMC ID : SIM-QM-MX-0000004M-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
1-butanol 1-butanol 98 to 100 0.22 99.74 to 99.84 0.22
  • Mechanism for measurement service delivery : Analytical services, DMR-165 x, DMR-380 x, DMR-480 x, DMR-517 x. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-014
  • CMC ID : SIM-QM-MX-000000XK-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/g Relative expanded uncertainty in % Mass fraction in mg/g Relative expanded uncertainty in %
Multi-component ethanol/water solution 1-pentanol 1 to 8 3 to 2 6 to 6.5 3 to 2
  • Mechanism for measurement service delivery : Analytical measurement and MRC DMR 380
  • Reference value assignment of VOC to PT and CRMs
  • Approved on 20 July 2020
  • Institute service identifier : 630-Q021-026
  • CMC ID : SIM-QM-MX-0000004L-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
1-pentanol 1-pentanol 98 to 100 0.22 99.74 to 99.84 0.22
  • Mechanism for measurement service delivery : Analytical services, DMR-165 x, DMR-380 x, DMR-480 x, DMR-517 x. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-013
  • CMC ID : SIM-QM-MX-000000XJ-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
1-propanol 1-propanol 98 to 100 0.22 99.74 to 99.84 0.22
  • Mechanism for measurement service delivery : Analytical services,DMR-418 x, DMR-165 x, DMR-380 x, DMR-480 x, DMR-517 x. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-011
  • CMC ID : SIM-QM-MX-000000XH-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/g Relative expanded uncertainty in % Mass fraction in mg/g Relative expanded uncertainty in %
Multi-component ethanol/water solution 1-propanol 1 to 8 3 to 2 6 to 6.5 3 to 2
  • Mechanism for measurement service delivery : Analytical measurement and MRC DMR 380
  • Reference value assignment of VOC to PT and CRMs
  • Approved on 20 July 2020
  • Institute service identifier : 630-Q021-024
  • CMC ID : SIM-QM-MX-0000004J-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in µg/g Relative expanded uncertainty in %
organic solution, multi-component 2,4'-DDD 100 to 1.00E5 7 to 1 3.29 3.2
  • Mechanism for measurement service delivery : DMR 277a
  • Reference value assignment of COPs in Calibration, solutions and matrix CRMs, and in PT´s services
  • Approved on 20 July 2020
  • Institute service identifier : 630-Q021.017
  • CMC ID : SIM-QM-MX-0000004C-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
2,4'-DDD 2,4'-DDD 98 to 100 5.3 99.33 to 99.34 5.3
  • Mechanism for measurement service delivery : Analytical services, DMR-277. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-048
  • CMC ID : SIM-QM-MX-000000YI-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
2,4'-DDE 2,4'-DDE 98 to 100 5.3 99.78 to 99.79 5.3
  • Mechanism for measurement service delivery : Analytical services, DMR-277. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-047
  • CMC ID : SIM-QM-MX-000000YH-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty in % Mass fraction in
organic solution, multi-component 2,4'-DDE 100 to 1.00E5 2.2 to 1.0E1
  • Mechanism for measurement service delivery : Analytical services, PT 630-IL-1203
  • Reference value assignment of COPs in Calibration, solutions and matrix CRMs, and in PT´s services
  • Approved on 20 July 2020
  • Institute service identifier : 630-Q021-004
  • CMC ID : SIM-QM-MX-0000003F-3
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in % Relative expanded uncertainty in % Mass fraction in % Relative expanded uncertainty in %
2,4'-DDT 2,4'-DDT 98 to 100 0.5 99.98 to 99.99 0.5
  • Mechanism for measurement service delivery : Analytical services, DMR-277. Some of these reference materials are used as a primary reference material for preparing internal solutions.
  • Approved on 17 May 2020
  • Institute service identifier : 630-C014-050
  • CMC ID : SIM-QM-MX-000000YK-2
     

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.