Results for: New Zealand
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
183 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
New Zealand, MSL (Measurement Standards Laboratory)
Spectral properties of materials , Transmittance, diffuse, spectral : 1.00E-4 to 4.00E-3
Spectrally-neutral material
Absolute expanded uncertainty : 2.0E-4
Spectrophotometer, integrating sphere
Wavelength range : 400 nm to 1000 nm
Bandwidth : 1 nm to 3 nm
Specific measurement conditions : 0/d
Other types of material can also be calibrated
Approved on 20 October 2005
Institute service identifier : MSLT.O.020
CMC ID : APMP-PR-NZ-0000061W-1
 
Spectral properties of materials , Transmittance, diffuse, spectral, T : 0.1 to 1
Spectrally-neutral material
Relative expanded uncertainty
0.05T
Spectrophotometer, integrating sphere
Wavelength range : 300 nm to 400 nm
Bandwidth : 1 nm to 3 nm
Specific measurement conditions : 0/d
Other types of material can also be calibrated
Approved on 20 October 2005
Institute service identifier : MSLT.O.020
CMC ID : APMP-PR-NZ-0000062G-1
 
Properties of detectors , Responsivity, spectral power
Broadband detector
Relative expanded uncertainty : 8.0E-2 %
Monochromator and reference detectors
Wavelength range : 680 nm to 800 nm
Bandwidth : 1 nm to 5 nm
Power level : 0.1 µW to 10 µW
Approved on 20 October 2005
Institute service identifier : MSLT.O.040 or MSLT.O.009
CMC ID : APMP-PR-NZ-0000062B-1
 
Photometry , Illuminance responsivity, tungsten source
Illuminance meter
Relative expanded uncertainty : 0.8 %
Standard lamp
Illuminance : 10 lx to 3000 lx
Correlated colour temperature : 2700 K to 3000 K
Approved on 21 October 2001
Institute service identifier : MSLT.O.001, MSLT.O.016
CMC ID : APMP-PR-NZ-00000626-1
 
Items for defining ITS-90 , Temperature : 29.7646 °C
Gallium melting point cell
Absolute expanded uncertainty : 0.13 mK
Comparison with reference cell(s)
Temperature controlled furnaceModified on 09 February 2015
Approved on 24 June 2004
Institute service identifier : MSL/T3
CMC ID : APMP-T-NZ-000006Y0-1
 
Items for defining ITS-90 , Temperature : 419.527 °C
Zinc freezing point cell
Absolute expanded uncertainty : 1.9 mK
Comparison with reference cell(s)
Temperature controlled furnaceModified on 09 February 2015
Approved on 24 June 2004
Institute service identifier : MSL/T6
CMC ID : APMP-T-NZ-000006Y3-1
 
Items for defining ITS-90 , Temperature : 231.928 °C
Tin freezing point cell
Absolute expanded uncertainty : 0.82 mK
Comparison with reference cell(s)
Temperature controlled furnaceModified on 09 February 2015
Approved on 24 June 2004
Institute service identifier : MSL/T5
CMC ID : APMP-T-NZ-000006Y2-1
 
Items for defining ITS-90 , Temperature : -38.8344 °C
SPRT
Absolute expanded uncertainty : 0.4 mK
Mercury triple point cell
Fixed point cellModified on 09 February 2015
Approved on 24 June 2004
Institute service identifier : MSL/T7
CMC ID : APMP-T-NZ-000006Y4-1
 
Time interval , Time interval : 1.00E-7 s to 8.64E4 s
Time difference source
Absolute expanded uncertainty : 2 ns
Direct time interval measurement
Trigger level : > 0.5 V (50 Ohm)
Number of measurements : 10
Pulse rise time : < 50 ns for 5 V
Excluded DUT's effect
Approved on 12 February 2008
Institute service identifier : MSL/6
CMC ID : APMP-TF-NZ-00000B58-1
 
Frequency , Frequency : 0.1 MHz to 10 MHz
Local frequency standard
Relative expanded uncertainty : 2.0E-13 Hz/Hz
Phase comparison
Measurement time : 3 days
Amplitude : > 0.5 V (50 Ohm)
Excluded DUT's effect
Approved on 12 February 2008
Institute service identifier : MSL/3
CMC ID : APMP-TF-NZ-00000B5D-1
 
Impedance (up to the MHz range) , Inductance: self inductance, high values : 1 H to 100 H
Fixed inductor, variable inductor, inductance box: inductance
Absolute expanded uncertainty : 1 µH to 5.3E3 µH
{"row_1":{"col_1":"","col_2":"100 µH","col_3":"1 mH","col_4":"10 mH","col_5":"100 mH","col_6":"1 H","col_7":"10 H","col_8":"100 H"},"row_2":{"col_1":"1 Ω","col_2":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 0.2/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 0.0001 µH to 0.0053 µH","col_3":"-","col_4":"-","col_5":"-","col_6":"-","col_7":"-","col_8":"-"},"row_3":{"col_1":"10 Ω","col_2":"-","col_3":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 2/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 0.001 µH to 0.053 µH","col_4":"-","col_5":"-","col_6":"-","col_7":"-","col_8":"-"},"row_4":{"col_1":"100 Ω","col_2":"-","col_3":"-","col_4":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 20/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 0.01 µH to 0.53 µH","col_5":"-","col_6":"-","col_7":"-","col_8":"-"},"row_5":{"col_1":"1 kΩ","col_2":"-","col_3":"-","col_4":"-","col_5":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 200/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 0.1 µH to 5.3 µH","col_6":"-","col_7":"-","col_8":"-"},"row_6":{"col_1":"10 kΩ","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 2000/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 1 µH to 53 µH","col_7":"-","col_8":"-"},"row_7":{"col_1":"100 kΩ","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"-","col_7":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 20000/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 10 µH to 529 µH","col_8":"-"},"row_8":{"col_1":"1 MΩ","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"-","col_7":"-","col_8":"Q[0.000014<I>L</I>, 0.001<I>R</I>, 200000/<I>f</I>], <I>L</I> in µH, <I>R</I> in Ω, <I>f</I> in Hz Values range from 100 µH to 5288 µH"}}
Inductance expanded uncertainty expressed in µH as a function of range of the Universal impedance bridge
L and R are the measured values
Universal impedance bridge
Frequency : 40 Hz to 2 kHz
Series resistance : 0 Ω to 1 MΩ
Approved on 22 November 2006
Institute service identifier : 43
CMC ID : APMP-EM-NZ-00000DA0-1
 
DC resistance , DC resistance meters: intermediate values : 1 Ω to 1.00E4 Ω
Ohmmeter, multimeter, multifunction transfer standard, resistance bridge
Relative expanded uncertainty : 0.12 µΩ/Ω
Resistance meters and resistance standards
Temperature : 15 °C to 25 °C
Approved on 22 November 2006
Institute service identifier : 19
CMC ID : APMP-EM-NZ-00000DBO-1
 
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 12 V to 1100 V
DC voltmeter, multimeter, multifunction transfer standard
Relative expanded uncertainty : 0.5 µV/V
Comparison with reference standard
Ambient temperature : 15 °C to 30 °C
Approved on 22 November 2006
Institute service identifier : 4
CMC ID : APMP-EM-NZ-00000DBA-1
 
DC resistance , DC resistance standards and sources: low values : 10 mΩ to 1000 mΩ
Fixed resistors, resistance box
Relative expanded uncertainty : 2.5E1 µΩ/Ω
Voltage comparator
Current : below or equal to 1 A
Voltage : above or equal to 10 mV
Approved on 22 November 2006
Institute service identifier : 16
CMC ID : APMP-EM-NZ-00000DBK-1
 
DC resistance , DC resistance standards and sources: standards for high current : 0.1 mΩ to 1000 mΩ
Fixed resistors: resistance R
Relative expanded uncertainty
63R -0.35

R in mΩ

The uncertainty is expressed in µΩ/Ω

Current comparator
Current : 1 A to 875 A
Voltage : 10 mV to 1 V
Expanded uncertainty values range from 141 to 6 µΩ/Ω
Approved on 22 November 2006
Institute service identifier : 17
CMC ID : APMP-EM-NZ-00000DBL-1
 
DC current (up to 100 A) , DC current sources: high values : 20 A to 100 A
Current generator
Relative expanded uncertainty : 1.8E1 µA/A to 3.6E1 µA/A
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µA/A)"},"row_2":{"col_1":"10 pA","col_2":"560"},"row_3":{"col_1":"100 pA","col_2":"540"},"row_4":{"col_1":"1 nA","col_2":"150"},"row_5":{"col_1":"10 nA","col_2":"20"},"row_6":{"col_1":"100 nA","col_2":"10"},"row_7":{"col_1":"1 µA","col_2":"10"},"row_8":{"col_1":"10 µA","col_2":"5"},"row_9":{"col_1":"100 µA","col_2":"5"},"row_10":{"col_1":"1 mA","col_2":"5"},"row_11":{"col_1":"10 mA","col_2":"5"},"row_12":{"col_1":"100 mA","col_2":"5"},"row_13":{"col_1":"1 A","col_2":"5"},"row_14":{"col_1":"10 A","col_2":"13"},"row_15":{"col_1":"20 A","col_2":"18"},"row_16":{"col_1":"100 A","col_2":"36"}}
Voltage across resistor
Expanded uncertainty values range from 18 µA/A to 97 µA/A
Approved on 22 November 2006
Institute service identifier : 31
CMC ID : APMP-EM-NZ-00000DC3-1
 
DC resistance , DC resistance standards and sources: high values : 1.00E-3 GΩ to 1 GΩ
Fixed resistor, three terminal resistor, resistance box: resistance R
Relative expanded uncertainty
0.7 + 27R - 20R 3

R in GΩ

The uncertainty is expressed in µΩ/Ω

Dual voltage source
Applied voltages : 5 V to 100 V
Temperature : 15 °C to 25 °C
Approved on 31 October 2016
Institute service identifier : 14
CMC ID : APMP-EM-NZ-00000DBI-1
 
High voltage and current , High DC voltage: ratios : 2.00E-5 to 1
High voltage resistive divider, DC high voltage probe
Relative expanded uncertainty : 3 mV/V
Reference divider
Input voltage : 1 kV to 50 kV
Approved on 10 November 2014
Institute service identifier : 11
CMC ID : APMP-EM-NZ-00000DBE-1
 
Mass , Mass : 10 g to 100 g
Mass standard
Absolute expanded uncertainty : 4 µg to 8 µg
Comparison in air
Approved on 14 April 2005
Institute service identifier : MSL/4
CMC ID : APMP-M-NZ-00000G52-1
 
Density , Density of solid : 1400 kg/m3 to 2500 kg/m3
Solid density artifact
Relative expanded uncertainty : 1.0E-5
Comparison in liquid
Mass : 400 g to 200 g
Temperature : 17 °C to 23 °C
Approved on 14 April 2005
Institute service identifier : MSL/10
CMC ID : APMP-M-NZ-00000G5B-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.