Results for: North Macedonia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
21 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
North Macedonia, BOM (Bureau of Metrology, Ministry of Economy (North Macedonia))
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 85 °C to 250 °C
LIG thermometer
Relative expanded uncertainty : 2.5E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-01
CMC ID : EURAMET-T-MK-000007VD-1
 
Fluid flow , Volume of liquid : 2 L to 20 L
Standard test measures
Relative expanded uncertainty : 3.0E-2 %
Volumetric
Liquid : water
Reference temperature : 15 °C
Approved on 11 September 2019
Institute service identifier : BOM4
CMC ID : EURAMET-M-MK-000009G0-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 200 °C to 300 °C
Industrial Platinum Resistance Thermometer
Relative expanded uncertainty : 2.5E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-03
CMC ID : EURAMET-T-MK-000007V9-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 10 °C to 85 °C
LIG thermometer
Relative expanded uncertainty : 2.0E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-01
CMC ID : EURAMET-T-MK-000007VC-1
 
Mass , Mass : 1 mg to 100 mg
Mass standard
Absolute expanded uncertainty : 1 µg to 2 µg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FQ-1
 
Fluid flow , Volume of liquid : 10 µL to 2.00E4 µL
Micropipettes or piston pipettes
Relative expanded uncertainty : 0.38 % to 0.2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : BOM1
CMC ID : EURAMET-M-MK-000009FX-2
 
Fluid flow , Volume of liquid : 1 mL to 1.00E4 mL
Glassware equipment: Pipettes, flasks, burettes, cylinders
Relative expanded uncertainty : 3.0E-2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : BOM7
CMC ID : EURAMET-M-MK-000009G3-2
 
Fluid flow , Volume of liquid : 50 L to 1.00E4 L
Proving tanks
Relative expanded uncertainty : 3.0E-2 %
Volumetric
Liquid : water
Reference temperature : 15 °C
Approved on 11 September 2019
Institute service identifier : BOM5
CMC ID : EURAMET-M-MK-000009G1-2
 
Mass , Mass : 0.1 kg to 1 kg
Mass standard
Absolute expanded uncertainty : 5.7E1 µg to 2.0E2 µg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FU-1
 
Mass , Mass : 10 g to 100 g
Mass standard
Absolute expanded uncertainty : 1.6E1 µg to 5.7E1 µg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FT-1
 
Mass , Mass : 10 kg to 20 kg
Mass standard
Absolute expanded uncertainty : 3.2 mg to 1.6E1 mg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FW-1
 
Mass , Mass : 1 g to 10 g
Mass standard
Absolute expanded uncertainty : 4 µg to 1.6E1 µg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FS-1
 
Mass , Mass : 0.1 g to 1 g
Mass standard
Absolute expanded uncertainty : 2 µg to 4 µg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FR-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 85 °C to 200 °C
IPRT and corresponding Temperature sensor with display units
Relative expanded uncertainty : 2.5E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-03
CMC ID : EURAMET-T-MK-000007V8-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 10 °C to 85 °C
IPRT and corresponding Temperature sensor with display units
Relative expanded uncertainty : 2.0E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-03
CMC ID : EURAMET-T-MK-000007V7-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 200 °C to 420 °C
Temperature sensor with display unit
Relative expanded uncertainty : 0.5 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-02
CMC ID : EURAMET-T-MK-000007VA-1
 
Fluid flow , Volume of liquid : 1 L to 50 L
Standard test measures, proving tanks, overflow pippetes
Relative expanded uncertainty : 8.5E-3 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : BOM9
CMC ID : EURAMET-M-MK-000009G4-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -60 °C to 10 °C
IPRT and corresponding Temperature sensor with display units
Relative expanded uncertainty : 2.0E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-03
CMC ID : EURAMET-T-MK-000007V6-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -60 °C to 10 °C
LIG thermometer
Relative expanded uncertainty : 2.0E-2 °C
Calibration by comparison
Approved on 07 September 2016
Institute service identifier : BoM/04-T-01
CMC ID : EURAMET-T-MK-000007VB-1
 
Mass , Mass : 1 kg to 10 kg
Mass standard
Absolute expanded uncertainty : 0.2 mg to 3.2 mg
Comparison in air
Uncertainty scales with measurand level The volume of the mass standards is known
Approved on 09 July 2013
Institute service identifier : BOM/0802
CMC ID : EURAMET-M-MK-000009FV-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.