Results for: Panama
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
38 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Panama, CENAMEP AIP (Centro Nacional de Metrología de Panama AIP)
Mass , Mass : 500 mg
Mass standard
Absolute expanded uncertainty : 2.5E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-500mg
CMC ID : SIM-M-PA-0000056C-1
 
Mass , Mass : 1 mg
Mass standard
Absolute expanded uncertainty : 6.0E-3 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-1mg
CMC ID : SIM-M-PA-00000564-1
 
Mass , Mass : 10 g
Mass standard
Absolute expanded uncertainty : 6.0E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-10g
CMC ID : SIM-M-PA-0000056G-1
 
Frequency , Frequency : 100 kHz
Local frequency standard
Relative expanded uncertainty : 6.0E-13 Hz/Hz
Direct frequency measurement with a signal mixer
Averaging time : 1 d
Amplitude : 0.5 V to 5 V
Approved on 25 October 2011
Institute service identifier : CMP-F0-S005
CMC ID : SIM-TF-PA-000005VY-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-13 Hz/Hz
Direct frequency measurement with a signal mixer
Averaging time : 1 d
Amplitude : 0.5 V to 5 V
Approved on 25 October 2011
Institute service identifier : CMP-F0-S005
CMC ID : SIM-TF-PA-000005W0-1
 
Mass , Mass : 100 g
Mass standard
Absolute expanded uncertainty : 0.15 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-100g
CMC ID : SIM-M-PA-0000056J-1
 
Mass , Mass : 200 g
Mass standard
Absolute expanded uncertainty : 0.3 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-200g
CMC ID : SIM-M-PA-0000056K-1
 
Mass , Mass : 50 g
Mass standard
Absolute expanded uncertainty : 0.1 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-50g
CMC ID : SIM-M-PA-0000056I-1
 
Mass , Mass : 1 kg
Mass standard
Absolute expanded uncertainty : 1.5 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-1kg
CMC ID : SIM-M-PA-0000056M-1
 
AC current , AC current up to 100 A: meters : 0.1 A to 2 A
Multimeter
Relative expanded uncertainty : 2.0E2 µA/A to 3.3E2 µA/A
{"row_1":{"col_1":"","col_2":"60 Hz","col_3":"1 kHz","col_4":"5 kHz"},"row_2":{"col_1":"100 mA","col_2":"300","col_3":"225","col_4":"300"},"row_3":{"col_1":"200 mA","col_2":"225","col_3":"200","col_4":"275"},"row_4":{"col_1":"1 A","col_2":"325","col_3":"325","col_4":"-"},"row_5":{"col_1":"2 A","col_2":"315","col_3":"315","col_4":"-"}}
The expanded uncertainty given in this table is expressed in µA/A
Direct comparison
Frequency : 60 Hz to 5 kHz
Approved on 04 April 2017
Institute service identifier : CENAMEP AIP/CMP-E4-S001
CMC ID : SIM-EM-PA-000008O3-1
 
DC current (up to 100 A) , DC current meters: intermediate values : 1.00E-4 A to 2 A
Multimeter
Relative expanded uncertainty : 5.5E1 µA/A to 1.2E2 µA/A
{"row_1":{"col_1":"","col_2":"Expanded uncertainty in µA/A"},"row_2":{"col_1":"100 µA to 200 µA","col_2":"120"},"row_3":{"col_1":"> 0.2 mA to 1 mA","col_2":"80"},"row_4":{"col_1":"> 1 mA to 100 mA","col_2":"55"},"row_5":{"col_1":"> 100 mA to 200 mA","col_2":"70"},"row_6":{"col_1":"> 0.2 A to 2 A","col_2":"100"}}
Direct comparison
Approved on 04 April 2017
Institute service identifier : CENAMEP AIP/CMP-E4-S001
CMC ID : SIM-EM-PA-000008O1-1
 
Frequency , Frequency : 1 Hz to 2.25E8 Hz
General frequency source
Relative expanded uncertainty : 2.0E-11 Hz/Hz
Direct frequency measurement with a signal mixer
Averaging time : 100 s
Amplitude : 0.5 V to 5 V
Number of measurements : 360
Approved on 25 October 2011
Institute service identifier : CMP-F0-S006
CMC ID : SIM-TF-PA-000005W2-1
 
Frequency , Frequency : 1.00E6 Hz to 3.00E9 Hz
Frequency counter
Relative expanded uncertainty : 5.0E-11 Hz/Hz
Using frequency synthetizers with an external timebase from atomic standard
Averaging time : 10 s
Approved on 25 October 2011
Institute service identifier : CMP-F0-S007
CMC ID : SIM-TF-PA-000005W5-1
 
Frequency , Frequency : 1 MHz
Local frequency standard
Relative expanded uncertainty : 6.0E-13 Hz/Hz
Direct frequency measurement with a signal mixer
Averaging time : 1 d
Amplitude : 0.5 V to 5 V
Approved on 25 October 2011
Institute service identifier : CMP-F0-S005
CMC ID : SIM-TF-PA-000005VZ-1
 
Mass , Mass : 20 g
Mass standard
Absolute expanded uncertainty : 8.0E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-20g
CMC ID : SIM-M-PA-0000056H-1
 
Time interval , Time interval : 10 s to 8.64E4 s
Time difference meter
Absolute expanded uncertainty : 5.0E-2 s
Direct measurement comparison with reference to local standard
Averaging time : 10 s to 86400 s
The service refers to the calibration of time interval measurement devices such as stopwatches, timers, digital and analog clocks for example.
Approved on 25 October 2011
Institute service identifier : CMP-F0-S002
CMC ID : SIM-TF-PA-000005VW-1
 
Mass , Mass : 100 mg
Mass standard
Absolute expanded uncertainty : 1.5E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-100mg
CMC ID : SIM-M-PA-0000056A-1
 
Mass , Mass : 200 mg
Mass standard
Absolute expanded uncertainty : 2.0E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-200mg
CMC ID : SIM-M-PA-0000056B-1
 
Mass , Mass : 50 mg
Mass standard
Absolute expanded uncertainty : 1.2E-2 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-50mg
CMC ID : SIM-M-PA-00000569-1
 
Mass , Mass : 10 mg
Mass standard
Absolute expanded uncertainty : 8.0E-3 mg
Direct comparison
Temperature : ((19 to 24) ± 1) °C
Humidity : ((40 to 60) ± 5) %
Approved on 08 September 2006
Institute service identifier : SRV-CMP-M1-F1-10mg
CMC ID : SIM-M-PA-00000567-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.