Results for: Philippines
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
33 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Philippines, NMLPHIL (National Metrology Laboratory of the Philippines)
Mass , Mass : 100 g
Mass standard
Absolute expanded uncertainty : 0.16 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/14
CMC ID : APMP-M-PH-000006DZ-1
 
Mass , Mass : 5 g
Mass standard
Absolute expanded uncertainty : 5.0E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/10
CMC ID : APMP-M-PH-000006DV-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 90 °C
Temperature sensor with display unit
Absolute expanded uncertainty : 3.0E1 mK
Comparison in liquid bath
IPRT (Hyteresis included) and thermistor sensors, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /DT
CMC ID : APMP-T-PH-0000076O-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 90 °C to 250 °C
IPRT
Absolute expanded uncertainty : 3.0E1 mK
Comparison in liquid bath
Hysteresis included, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /IPRT
CMC ID : APMP-T-PH-0000076L-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
IPRT
Absolute expanded uncertainty : 1.0E1 mK
Comparison in ice bath
Hysteresis included, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /IPRT
CMC ID : APMP-T-PH-0000076M-1
 
Mass , Mass : 200 mg
Mass standard
Absolute expanded uncertainty : 2.0E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/6
CMC ID : APMP-M-PH-000006DR-1
 
Mass , Mass : 500 mg
Mass standard
Absolute expanded uncertainty : 2.5E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/7
CMC ID : APMP-M-PH-000006DS-1
 
Mass , Mass : 10 mg
Mass standard
Absolute expanded uncertainty : 8.0E-3 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/2
CMC ID : APMP-M-PH-000006DN-1
 
Mass , Mass : 5 kg
Mass standard
Absolute expanded uncertainty : 8 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/19
CMC ID : APMP-M-PH-000006E4-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -30 °C to 0 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty : 4.5E1 mK
Comparison in liquid bath
Total, Mercury-filled, Graduation 0.05 °C, Points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /LIGT
CMC ID : APMP-T-PH-0000076Q-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 90 °C to 250 °C
Temperature sensor with display unit
Absolute expanded uncertainty : 3.0E1 mK
Comparison in liquid bath
IPRT (Hyteresis included) and thermistor sensors, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /DT
CMC ID : APMP-T-PH-0000076P-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -30 °C to 0 °C
Temperature sensor with display unit
Absolute expanded uncertainty : 3.0E1 mK
Comparison in liquid bath
IPRT (Hyteresis included) and thermistor sensors, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /DT
CMC ID : APMP-T-PH-0000076N-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -30 °C to 0 °C
IPRT
Absolute expanded uncertainty : 2.5E1 mK
Comparison in liquid bath
Hysteresis included, points only
Approved on 10 November 2015
Institute service identifier : NMLPHIL /IPRT
CMC ID : APMP-T-PH-0000076J-1
 
Pressure , Gauge pressure: liquid medium : 1.25 MPa to 100 MPa
Pressure gauge
Absolute expanded uncertainty : 4.1E2 Pa to 8.3E3 Pa
1.1E-04P 
8.3E-05P P, pressure  in Pa
1.1E-04P but not less than 410 Pa for : 1.25 MPa to 6.8 MPa
8.3E-05but not less than 630 Pa for : >6.8 to 100 MPa
Direct comparison with pressure standard
Pressure Balance
Approved on 22 August 2022
CMC ID : APMP-M-PH-00000KIT-1
 
Mass , Mass : 100 mg
Mass standard
Absolute expanded uncertainty : 1.8E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/5
CMC ID : APMP-M-PH-000006DQ-1
 
Mass , Mass : 50 mg
Mass standard
Absolute expanded uncertainty : 1.2E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/4
CMC ID : APMP-M-PH-000006DP-1
 
Mass , Mass : 500 g
Mass standard
Absolute expanded uncertainty : 0.8 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/16
CMC ID : APMP-M-PH-000006E1-1
 
Mass , Mass : 10 kg
Mass standard
Absolute expanded uncertainty : 1.6E1 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/20
CMC ID : APMP-M-PH-000006E5-1
 
Mass , Mass : 1 mg to 5 mg
Mass standard
Absolute expanded uncertainty : 6.0E-3 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/1
CMC ID : APMP-M-PH-000006DM-1
 
Mass , Mass : 20 mg
Mass standard
Absolute expanded uncertainty : 1.0E-2 mg
Comparison in air
Approved on 18 December 2013
Institute service identifier : NMLPHIL/TSWT/3
CMC ID : APMP-M-PH-000006DO-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.