Results for: Serbia Electricity and Magnetism
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
40 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Serbia, DMDM (Directorate of Measures and Precious Metals)
DC voltage (up to 1100 V) , DC voltage sources: single values : 1 V to 10 V
Standard cell, solid state voltage standard
Absolute expanded uncertainty : 0.45 µV to 1.0E1 µV
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / µV ","col_3":"Reference Stanard used in calibration"},"row_2":{"col_1":"1.018 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_3":{"col_1":"1 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_4":{"col_1":"10 V","col_2":"0.04","col_3":"Josephson Voltage Standard"},"row_5":{"col_1":"1.018 V","col_2":"0.45","col_3":"Group of standard cells and solid state voltage standards"},"row_6":{"col_1":"1 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"},"row_7":{"col_1":"10 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"}}
Difference measurement
Fixed voltage : 1.018 V, 1 V, 10 V
Approved on 06 August 2013
Institute service identifier : DMDM/1
CMC ID : EURAMET-EM-RS-00000ERH-1
 
DC resistance , DC resistance standards and sources: high values : 1.00E7 Ω to 1.00E9 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 6.0E1 µΩ/Ω to 5.0E3 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µΩ/Ω)"},"row_2":{"col_1":"100 µΩ","col_2":"20"},"row_3":{"col_1":"1 mΩ","col_2":"10"},"row_4":{"col_1":"10 mΩ","col_2":"2.5"},"row_5":{"col_1":"100 mΩ","col_2":"1.5"},"row_6":{"col_1":"1 Ω","col_2":"0.2"},"row_7":{"col_1":"10 Ω","col_2":"0.33"},"row_8":{"col_1":"100 Ω","col_2":"0.39"},"row_9":{"col_1":"1000 Ω","col_2":"0.24"},"row_10":{"col_1":"10000 Ω","col_2":"0.29"},"row_11":{"col_1":"100 kΩ","col_2":"2.6"},"row_12":{"col_1":"1 MΩ","col_2":"6.5"},"row_13":{"col_1":"10 MΩ","col_2":"60"},"row_14":{"col_1":"100 MΩ","col_2":" 500"},"row_15":{"col_1":"1 GΩ","col_2":"5000"}}
Comparison by means of a binary voltage divider bridge
Voltage : 90.9 V
Fixed resistor in oil or air bath, temperature: 23 °C
Approved on 06 January 2015
Institute service identifier : DMDM/121
CMC ID : EURAMET-EM-RS-00000ESJ-1
 
Impedance (up to the MHz range) , Capacitance for dielectric capacitors : 0.01 nF to 1.00E4 nF
Fixed capacitor, switched capacitor, capacitance box
Relative expanded uncertainty : 0.59 mF/F to 8.1 mF/F
{"row_1":{"col_1":"","col_2":"20 Hz","col_3":"120 Hz","col_4":"1 kHz","col_5":"10 kHz","col_6":"100 kHz","col_7":"1 MHz","col_8":"2 MHz"},"row_2":{"col_1":"0.01 nF","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"0.81","col_7":"0.72 to 0.81","col_8":"0.84"},"row_3":{"col_1":"0.1 nF","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"0.62","col_7":"0.61 to 0.63","col_8":"0.71"},"row_4":{"col_1":"1 nF","col_2":"-","col_3":"-","col_4":"0.71 to 1.31","col_5":"-","col_6":"-","col_7":"0.59 to 0.69","col_8":"0.60 to 0.78"},"row_5":{"col_1":"100 nF","col_2":"-","col_3":"0.6","col_4":"-","col_5":"-","col_6":"0.69","col_7":"-","col_8":"-"},"row_6":{"col_1":"10000 nF","col_2":"3.06","col_3":"3.06","col_4":"3.1","col_5":"3.56","col_6":"8.07","col_7":"-","col_8":"-"}}
The expanded uncertainties given in this table are expressed in mF/F
LCR meter
Frequency : 20 Hz to 2 MHz
Approved on 06 August 2013
Institute service identifier : DMDM/109
CMC ID : EURAMET-EM-RS-00000ES4-1
 
Impedance (up to the MHz range) , Capacitance: meters : 1 pF to 1000 pF
Capacitance bridge, LCR meter
Relative expanded uncertainty : 5.0E-3 mF/F to 0.26 mF/F
{"row_1":{"col_1":"","col_2":" 1 kHz","col_3":"100 Hz to 1 MHz"},"row_2":{"col_1":"1 pF","col_2":"0.01","col_3":"0.03 to 0.26"},"row_3":{"col_1":"10 pF","col_2":"0.007","col_3":"0.012 to 0.13"},"row_4":{"col_1":"100 pF","col_2":"0.007","col_3":"0.012 to 0.09"},"row_5":{"col_1":"1000 pF","col_2":"0.005","col_3":"0.01 to 0.014"}}
The expanded uncertainties given in this table are expressed in mF/F
Direct measurement
Frequency : 100 Hz to 1 MHz
Approved on 06 August 2013
Institute service identifier : DMDM/110
CMC ID : EURAMET-EM-RS-00000ES5-1
 
DC current (up to 100 A) , DC current sources: low values : 0.1 mA
Current generator, multifunction calibrator
Absolute expanded uncertainty : 1.3 nA
Voltage drop across standard resistor
Power dissipation of standard resistor : 0.1 mW
Approved on 06 August 2013
Institute service identifier : DMDM/78
CMC ID : EURAMET-EM-RS-00000ERI-1
 
DC resistance , DC resistance standards and sources: intermediate values : 10 Ω to 1.00E6 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 0.24 µΩ/Ω to 6.5 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µΩ/Ω)"},"row_2":{"col_1":"100 µΩ","col_2":"20"},"row_3":{"col_1":"1 mΩ","col_2":"10"},"row_4":{"col_1":"10 mΩ","col_2":"2.5"},"row_5":{"col_1":"100 mΩ","col_2":"1.5"},"row_6":{"col_1":"1 Ω","col_2":"0.2"},"row_7":{"col_1":"10 Ω","col_2":"0.33"},"row_8":{"col_1":"100 Ω","col_2":"0.39"},"row_9":{"col_1":"1000 Ω","col_2":"0.24"},"row_10":{"col_1":"10000 Ω","col_2":"0.29"},"row_11":{"col_1":"100 kΩ","col_2":"2.6"},"row_12":{"col_1":"1 MΩ","col_2":"6.5"},"row_13":{"col_1":"10 MΩ","col_2":"60"},"row_14":{"col_1":"100 MΩ","col_2":" 500"},"row_15":{"col_1":"1 GΩ","col_2":"5000"}}
Comparison by means of a direct current comparator bridge, comparison by means of a binary voltage divider bridge
Power : 10 mW up to 10 kΩ
Voltage : 18.18 V for 100 kΩ, 45.5 V for 1 MΩ
Fixed resistor in oil bath, temperature: 23 °C
Approved on 06 January 2015
Institute service identifier : DMDM/18
CMC ID : EURAMET-EM-RS-00000ES1-1
 
High voltage and current , High AC voltage: voltage transformer phase displacement : 0 mrad to 30 mrad
Voltage transformer
Absolute expanded uncertainty : 0.1 mrad to 0.15 mrad
{"row_1":{"col_1":"","col_2":"Expanded uncertainty"},"row_2":{"col_1":"100/√3 V to 600/√3 V","col_2":"0.10"},"row_3":{"col_1":"600 V to 4000 V","col_2":"0.10"},"row_4":{"col_1":"5000 V to 35000 V","col_2":"0.10"},"row_5":{"col_1":"40000/√3 V to 120000/√3 V","col_2":"0.15"}}
Frequency: 50 Hz
The expanded uncertainties given in this table are expressed in mrad
Direct comparison
Primary voltage : 100/√3 V to 120/√3 kV
Secondary voltage : 100/√3 V, 110/√3 V, 100 V, 110 V, 120 V
Frequency : 50 Hz
Uncertainties are minimum and maximum values.
Approved on 07 February 2019
Institute service identifier : DMDM/117
CMC ID : EURAMET-EM-RS-00000ERQ-1
 
Other DC and low frequency measurements , Current and voltage waveform: mains frequency current harmonics : 0.016 A to 10 A
Mains frequency harmonics analyser
Relative expanded uncertainty : 0.4 mA/A to 2.9 mA/A
{"row_1":{"col_1":"","col_2":"1","col_3":"2 to 9","col_4":"10 to 17","col_5":"18 to 50"},"row_2":{"col_1":"0.016 A to 10 A","col_2":"0.4","col_3":"-","col_4":"-","col_5":"-"},"row_3":{"col_1":"(0.016 A to 10 A)/<I>n</I>","col_2":"-","col_3":"1.4","col_4":"1.7","col_5":"2.9"}}
n: number of harmonics
The expanded uncertainties given in this table are expressed in mA/A
Comparison
Harmonic number : 1 to 50
For IEC 61000-3-2, IEC 61000-3-3, current in A dependent on wave shape.
Approved on 07 February 2019
Institute service identifier : DMDM/120
CMC ID : EURAMET-EM-RS-00000ESI-1
 
DC current (up to 100 A) , DC current sources: intermediate values : 1.00E-4 A to 20 A
Current generator, multifunction calibrator
Absolute expanded uncertainty : 1.3E-3 µA to 4.8E3 µA
{"row_1":{"col_1":"","col_2":"Power dissipation","col_3":"Expanded uncertainty"},"row_2":{"col_1":"0.1 mA to 1 mA","col_2":"up to 10 mW","col_3":"1.3 nA to 12 nA"},"row_3":{"col_1":"1 mA to 3 mA","col_2":"up to 10 mW","col_3":"12 nA to 35 nA"},"row_4":{"col_1":"3 mA to 10 mA","col_2":"up to 10 mW","col_3":"33 nA to 98 nA"},"row_5":{"col_1":"10 mA to 30 mA","col_2":"up to 10 mW","col_3":"0.14 µA to 0.33 µA"},"row_6":{"col_1":"30 mA to 100 mA","col_2":"up to 10 mW","col_3":"1.2 µA to 1.4 µA"},"row_7":{"col_1":"0.1 A to 1 A","col_2":"up to 100 mW","col_3":"11 µA to 16 µA"},"row_8":{"col_1":"1 A to 3 A","col_2":"up to 100 mW","col_3":"0.11 mA to 0.32 mA"},"row_9":{"col_1":"3 A to 10 A","col_2":"up to 100 mW","col_3":"0.59 mA to 1.1 mA"},"row_10":{"col_1":"10 A to 20 A","col_2":"up to 100 mW","col_3":"3.9 mA to 4.4 mA"}}
Voltage drop across standard resistor
Power dissipation of standard resistor : up to 100 mW
Approved on 06 August 2013
Institute service identifier : DMDM/79
CMC ID : EURAMET-EM-RS-00000ERJ-1
 
AC power , AC power and energy: three phase : 0.4 Ws to 4.80E6 Ws
Energy meter
Relative expanded uncertainty : 1.2E2 µWh (VAh)-1 to 1.3E2 µWh (VAh)-1
Direct comparison
Voltage : 30 V to 480 V
Current : 0.05 A to 100 A
Power factor (reactive power factor) : 1 to 0.25, inductive or capacitive
Frequency : 50 Hz to 60 Hz
Measurement time : 1 s to 100 s
Range values per phase. Uncertainties are minimum and maximum values.
Approved on 06 August 2013
Institute service identifier : DMDM/106
CMC ID : EURAMET-EM-RS-00000ESH-1
 
Other DC and low frequency measurements , Phase angle: sources : 0 ° to 360 °
Phase source
Absolute expanded uncertainty : 4.0E-2 ° to 1.7 °
{"row_1":{"col_1":"","col_2":"<I>U</I><SUB>1</SUB> = <I>U</I><SUB>2</SUB>","col_3":"<I>U</I><SUB>2</SUB> / <I>U</I><SUB>1</SUB> &lt;= 1000"},"row_2":{"col_1":"1 Hz to 50 Hz","col_2":"0.06","col_3":"0.08 to 0.22"},"row_3":{"col_1":"50 Hz to 100 Hz","col_2":"0.04","col_3":"0.06 to 0.21"},"row_4":{"col_1":"100 Hz to 1 kHz","col_2":"0.08","col_3":"0.18 to 0.48"},"row_5":{"col_1":"1 kHz to 10 kHz","col_2":"0.08 to 0.14","col_3":"0.18 to 0.78"},"row_6":{"col_1":"10 kHz to 100 kHz","col_2":"0.14 to 0.83","col_3":"0.29 to 1.68"}}
U1 and U2 are the signals whose phase difference is measured
The expanded uncertainties given in this table are expressed in °
Direct measurement
Frequency : 1 Hz to 100 kHz
Voltage : 10 mV to 350 V
Approved on 06 August 2013
Institute service identifier : DMDM/108
CMC ID : EURAMET-EM-RS-00000ERT-1
 
DC current (up to 100 A) , DC current sources: high values : 20 A to 30 A
Current generator
Absolute expanded uncertainty : 4.8 mA to 6 mA
Voltage drop across standard resistor
Power dissipation of standard resistor : up to 100 mW
Approved on 06 August 2013
Institute service identifier : DMDM/88
CMC ID : EURAMET-EM-RS-00000ERK-1
 
DC current (up to 100 A) , DC current meters: low values : 0.1 mA
Ammeter, multimeter
Absolute expanded uncertainty : 1.3 nA
Voltage drop across standard resistor
Power dissipation of standard resistor : 0.1 mW
Approved on 06 August 2013
Institute service identifier : DMDM/89
CMC ID : EURAMET-EM-RS-00000ERL-1
 
DC resistance , DC resistance meters: low values : 1.00E-4 Ω to 1 Ω
Multimeter, resistance bridge
Relative expanded uncertainty : 2.0E1 µΩ/Ω to 0.2 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µΩ/Ω)"},"row_2":{"col_1":"100 µΩ","col_2":"20"},"row_3":{"col_1":"1 mΩ","col_2":"10"},"row_4":{"col_1":"10 mΩ","col_2":"2.5"},"row_5":{"col_1":"100 mΩ","col_2":"1.5"},"row_6":{"col_1":"1 Ω","col_2":"0.2"},"row_7":{"col_1":"10 Ω","col_2":"0.33"},"row_8":{"col_1":"100 Ω","col_2":"0.39"},"row_9":{"col_1":"1000 Ω","col_2":"0.24"},"row_10":{"col_1":"10000 Ω","col_2":"0.29"},"row_11":{"col_1":"100 kΩ","col_2":"2.6"},"row_12":{"col_1":"1 MΩ","col_2":"6.5"},"row_13":{"col_1":"10 MΩ","col_2":"60"},"row_14":{"col_1":"100 MΩ","col_2":" 500"},"row_15":{"col_1":"1 GΩ","col_2":"5000"}}
Direct method of measurement
Temperature: 23 °C
Approved on 06 January 2015
Institute service identifier : DMDM/31
CMC ID : EURAMET-EM-RS-00000ES2-1
 
AC voltage (up to the MHz range) , AC voltage: AC/DC transfer difference at medium voltage : 0.5 V to 5 V
AC-DC transfer standard, thermal converter
Relative expanded uncertainty : 1.0E1 µV/V to 5.6E1 µV/V
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"20 Hz","col_4":"40 Hz","col_5":"500 Hz","col_6":"1 kHz","col_7":"10 kHz","col_8":"20 kHz","col_9":"50 kHz","col_10":"100 kHz","col_11":"200 kHz","col_12":"500 kHz","col_13":"700 kHz","col_14":"1 MHz"},"row_2":{"col_1":"10 mV","col_2":"230","col_3":"220","col_4":"210","col_5":"220","col_6":"210","col_7":"220","col_8":"220","col_9":"220","col_10":"230","col_11":"220","col_12":"230","col_13":"230","col_14":"240"},"row_3":{"col_1":"20 mV","col_2":"110","col_3":"94","col_4":"96","col_5":"95","col_6":"91","col_7":"91","col_8":"91","col_9":"96","col_10":"100","col_11":"100","col_12":"110","col_13":"120","col_14":"150"},"row_4":{"col_1":"30 mV","col_2":"81","col_3":"64","col_4":"64","col_5":"60","col_6":"60","col_7":"60","col_8":"59","col_9":"64","col_10":"68","col_11":"73","col_12":"81","col_13":"100","col_14":"110"},"row_5":{"col_1":"60 mV","col_2":"55","col_3":"47","col_4":"47","col_5":"47","col_6":"47","col_7":"47","col_8":"47","col_9":"47","col_10":"47","col_11":"55","col_12":"64","col_13":"81","col_14":"90"},"row_6":{"col_1":"100 mV","col_2":"37","col_3":"37","col_4":"37","col_5":"37","col_6":"37","col_7":"37","col_8":"37","col_9":"33","col_10":"37","col_11":"33","col_12":"37","col_13":"46","col_14":"60"},"row_7":{"col_1":"200 mV","col_2":"37","col_3":"37","col_4":"37","col_5":"37","col_6":"37","col_7":"37","col_8":"37","col_9":"37","col_10":"33","col_11":"37","col_12":"46","col_13":"60","col_14":"60"},"row_8":{"col_1":"400 mV","col_2":"24","col_3":"24","col_4":"24","col_5":"17","col_6":"17","col_7":"17","col_8":"18","col_9":"18","col_10":"20","col_11":"28","col_12":"37","col_13":"47","col_14":"52"},"row_9":{"col_1":"600 mV","col_2":"17","col_3":"17","col_4":"17","col_5":"17","col_6":"17","col_7":"17","col_8":"17","col_9":"17","col_10":"20","col_11":"28","col_12":"37","col_13":"47","col_14":"52"},"row_10":{"col_1":"1 V","col_2":"14","col_3":"14","col_4":"13","col_5":"13","col_6":"13","col_7":"13","col_8":"13","col_9":"13","col_10":"14","col_11":"17","col_12":"24","col_13":"35","col_14":"44"},"row_11":{"col_1":"2 V","col_2":"11","col_3":"11","col_4":"11","col_5":"10","col_6":"10","col_7":"10","col_8":"10","col_9":"11","col_10":"11","col_11":"14","col_12":"23","col_13":"33","col_14":"43"},"row_12":{"col_1":"3 V","col_2":"12","col_3":"11","col_4":"11","col_5":"10","col_6":"10","col_7":"10","col_8":"10","col_9":"11","col_10":"11","col_11":"14","col_12":"23","col_13":"33","col_14":"43"},"row_13":{"col_1":"6 V","col_2":"18","col_3":"16","col_4":"15","col_5":"13","col_6":"13","col_7":"13","col_8":"13","col_9":"13","col_10":"16","col_11":"21","col_12":"28","col_13":"42","col_14":"56"},"row_14":{"col_1":"10 V","col_2":"23","col_3":"18","col_4":"18","col_5":"14","col_6":"14","col_7":"14","col_8":"14","col_9":"14","col_10":"18","col_11":"25","col_12":"32","col_13":"47","col_14":"64"},"row_15":{"col_1":"20 V","col_2":"27","col_3":"21","col_4":"21","col_5":"16","col_6":"16","col_7":"16","col_8":"16","col_9":"16","col_10":"22","col_11":"27","col_12":"37","col_13":"53","col_14":"73"},"row_16":{"col_1":"30 V","col_2":"30","col_3":"25","col_4":"24","col_5":"17","col_6":"17","col_7":"18","col_8":"18","col_9":"18","col_10":"25","col_11":"25","col_12":"-","col_13":"-","col_14":"-"},"row_17":{"col_1":"60 V","col_2":"39","col_3":"30","col_4":"29","col_5":"22","col_6":"22","col_7":"22","col_8":"22","col_9":"22","col_10":"30","col_11":"40","col_12":"-","col_13":"-","col_14":"-"},"row_18":{"col_1":"100 V","col_2":"40","col_3":"30","col_4":"30","col_5":"22","col_6":"22","col_7":"22","col_8":"22","col_9":"22","col_10":"30","col_11":"-","col_12":"-","col_13":"-","col_14":"-"},"row_19":{"col_1":"200 V","col_2":"43","col_3":"33","col_4":"33","col_5":"24","col_6":"24","col_7":"24","col_8":"24","col_9":"24","col_10":"33","col_11":"-","col_12":"-","col_13":"-","col_14":"-"},"row_20":{"col_1":"300 V","col_2":"48","col_3":"36","col_4":"37","col_5":"27","col_6":"27","col_7":"27","col_8":"27","col_9":"27","col_10":"36","col_11":"-","col_12":"-","col_13":"-","col_14":"-"},"row_21":{"col_1":"600 V","col_2":"53","col_3":"40","col_4":"40","col_5":"27","col_6":"27","col_7":"27","col_8":"27","col_9":"27","col_10":"40","col_11":"-","col_12":"-","col_13":"-","col_14":"-"},"row_22":{"col_1":"800 V","col_2":"58","col_3":"43","col_4":"40","col_5":"27","col_6":"27","col_7":"27","col_8":"27","col_9":"28","col_10":"42","col_11":"-","col_12":"-","col_13":"-","col_14":"-"},"row_23":{"col_1":"1000 V","col_2":"57","col_3":"43","col_4":"40","col_5":"27","col_6":"27","col_7":"27","col_8":"27","col_9":"28","col_10":"42","col_11":"-","col_12":"-","col_13":"-","col_14":"-"}}
The expanded uncertainties given in this table are expressed in µV/V
Comparison
Frequency : 10 Hz to 1 MHz
Approved on 06 August 2013
Institute service identifier : DMDM/46
CMC ID : EURAMET-EM-RS-00000ES8-1
 
AC power , AC power and energy: single phase (frequency <= 400 Hz) : 0 var to 4.80E4 var
Power meter, power converter
Relative expanded uncertainty : 3.7E1 µvar (VA)-1 to 1.3E2 µvar (VA)-1
{"row_1":{"col_1":"","col_2":"Voltage","col_3":"Current","col_4":"Frequency","col_5":"Direct comparison","col_6":"Sampling method"},"row_2":{"col_1":"0 var to 14000 var","col_2":"4 V to 700 V","col_3":"0.05 A to 20 A","col_4":"16 Hz to 400 Hz","col_5":"-","col_6":"37 µvar/VA to 50 µvar/VA"},"row_3":{"col_1":"0 var to 48000 var","col_2":"30 V to 480 V","col_3":"0.05 A to 100 A","col_4":"50 Hz to 60 Hz","col_5":"116 µvar/VA to 129 µvar/VA","col_6":"-"}}
Direct comparison or sampling method
Voltage : 4 V to 700 V
Current : 0.05 A to 100 A
Power factor : 1 to 0, inductive or capacitive
Frequency : 16 Hz to 400 Hz
Uncertainties are minimum and maximum values
Approved on 06 August 2013
Institute service identifier : DMDM/115
CMC ID : EURAMET-EM-RS-00000ESE-1
 
High voltage and current , High AC voltage: voltage transformer ratio error : 0 % to 2 %
Voltage transformer
Absolute expanded uncertainty : 1.0E-2 % to 2.0E-2 %
{"row_1":{"col_1":"","col_2":"Expanded uncertainty"},"row_2":{"col_1":"100/&radic;3 V to 600/&radic;3 V","col_2":"0.01"},"row_3":{"col_1":"600 V to 4000 V","col_2":"0.01"},"row_4":{"col_1":"5000 V to 35000 V","col_2":"0.01"},"row_5":{"col_1":"40000/&radic;3 V to 120000/&radic;3 V","col_2":"0.02"}}
Frequency: 50 Hz
The expanded uncertainties given in this table are expressed in %
Direct comparison
Primary voltage : 100/√3 V to 120/√3 kV
Secondary voltage : 100/√3 V, 110/√3 V, 100 V, 110 V, 120 V
Frequency : 50 Hz
Uncertainties are minimum and maximum values.
Approved on 07 February 2019
Institute service identifier : DMDM/116
CMC ID : EURAMET-EM-RS-00000ERP-1
 
DC voltage (up to 1100 V) , DC voltage sources: single values : 1 V to 10 V
Solid state voltage standard
Relative expanded uncertainty : 4.0E-2 µV/V to 0.12 µV/V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / µV ","col_3":"Reference Stanard used in calibration"},"row_2":{"col_1":"1.018 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_3":{"col_1":"1 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_4":{"col_1":"10 V","col_2":"0.04","col_3":"Josephson Voltage Standard"},"row_5":{"col_1":"1.018 V","col_2":"0.45","col_3":"Group of standard cells and solid state voltage standards"},"row_6":{"col_1":"1 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"},"row_7":{"col_1":"10 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"}}
Direct comparison with JVS
Fixed voltage : 1.018 V, 1 V, 10 V
Approved on 07 April 2016
Institute service identifier : DMDM/122
CMC ID : EURAMET-EM-RS-00000ESK-1
 
Impedance (up to the MHz range) , Inductance: meters : 0.1 mH to 1.00E4 mH
Inductance bridge, LCR meter
Relative expanded uncertainty : 0.2 mH/H to 0.5 mH/H
{"row_1":{"col_1":"","col_2":"100 Hz ","col_3":" 1 kHz"},"row_2":{"col_1":"0.1 mH to 1000 mH ","col_2":"-","col_3":"0.2"},"row_3":{"col_1":"1 H to 10 H ","col_2":"0.5","col_3":"0.2"}}
The expanded uncertainties given in this table are expressed in mH/H
Direct measurement
Frequency : 100 Hz, 1 kHz
Approved on 06 August 2013
Institute service identifier : DMDM/111
CMC ID : EURAMET-EM-RS-00000ES6-1
 
DC resistance , DC resistance meters: intermediate values : 0.01 kΩ to 1.00E6 kΩ
Ohmmeter, multimeter, resistance bridge
Relative expanded uncertainty : 0.24 µΩ/Ω to 5.0E3 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µΩ/Ω)"},"row_2":{"col_1":"100 µΩ","col_2":"20"},"row_3":{"col_1":"1 mΩ","col_2":"10"},"row_4":{"col_1":"10 mΩ","col_2":"2.5"},"row_5":{"col_1":"100 mΩ","col_2":"1.5"},"row_6":{"col_1":"1 Ω","col_2":"0.2"},"row_7":{"col_1":"10 Ω","col_2":"0.33"},"row_8":{"col_1":"100 Ω","col_2":"0.39"},"row_9":{"col_1":"1000 Ω","col_2":"0.24"},"row_10":{"col_1":"10000 Ω","col_2":"0.29"},"row_11":{"col_1":"100 kΩ","col_2":"2.6"},"row_12":{"col_1":"1 MΩ","col_2":"6.5"},"row_13":{"col_1":"10 MΩ","col_2":"60"},"row_14":{"col_1":"100 MΩ","col_2":" 500"},"row_15":{"col_1":"1 GΩ","col_2":"5000"}}
Direct method of measurement
Temperature: 23 °C
Approved on 06 January 2015
Institute service identifier : DMDM/36
CMC ID : EURAMET-EM-RS-00000ES3-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.