Tunisia, DEF-NAT (Laboratoire de Métrologie de la Direction Générale des Transmissions et de l'Informatique)
DC voltage (up to 1100 V) , DC voltage sources : intermediate values : 10 V to 1000 V
voltage source, multifunction calibrator
Absolute expanded uncertainty : 5.1E-5 V to 6.8E-3 V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / V"},"row_2":{"col_1":"10 V to 100 V","col_2":"(4.8E-06 <i>U</i> + 1.7E-06)"},"row_3":{"col_1":"100 V to 1000 V","col_2":"(6.8E-06 <i>U</i> + 2.2E-06)"}}
Comparison to a voltage reference via a DC comparator with a resistive divider
Temperature : (23 ± 1)°C
Approved on 22 November 2016
Institute service identifier : DEF-NAT 1.1.3
CMC ID : AFRIMETS-EM-TN-00000871-1
 
Time interval , Time interval : 1.00E-8 s to 1.00E-3 s
Rise/fall time meter
Absolute expanded uncertainty
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in s"},"row_2":{"col_1":"1.00E-08 s","col_2":"2.7E-09"},"row_3":{"col_1":"1.00E-07 s","col_2":"9.0E-09"},"row_4":{"col_1":"1.00E-06 s","col_2":"7.2E-08"},"row_5":{"col_1":"1.00E-05 s","col_2":"7.0E-07"},"row_6":{"col_1":"1.00E-04 s","col_2":"7.0E-06"},"row_7":{"col_1":"1.00E-03 s","col_2":"7.0E-05"}}
7E-02t + 2E-09

t rise/fall time in s, values range from 2.7E-09 s to 7E-05 s

The uncertainty is expressed in s

Time interval measurement
Amplitude : >= 1 V in 50 ohms
Slew rate : > 1 V/ns Number of measurements : 10
Approved on 27 March 2017
Institute service identifier : DEF-NAT 3.4.1
CMC ID : AFRIMETS-TF-TN-000008LU-1
 
Radio frequency measurements , Reflection coefficient (Sii) in coaxials (values in linear terms: magnitude) : 2.00E-3 to 0.5
Passive devices
Absolute expanded uncertainty : 6.2E-4 to 3.3E-2
{"row_1":{"col_1":"Γ<sub>x</sub><br>","col_2":"0.4 Ghz to 1 Ghz","col_3":"1 Ghz to 12.4 Ghz<br>"},"row_2":{"col_1":"0.5","col_2":"0.0330","col_3":"0.0330"},"row_3":{"col_1":"0.3","col_2":"0.02","col_3":"0.02"},"row_4":{"col_1":"0.2","col_2":"0.0130","col_3":"0.0140"},"row_5":{"col_1":"0.1","col_2":"0.0065","col_3":"0.0068"},"row_6":{"col_1":"0.05","col_2":"0.0033","col_3":"0.0039"},"row_7":{"col_1":"0.03","col_2":"0.0021","col_3":"0.0029"},"row_8":{"col_1":"0.02<br>","col_2":"0.0015<br>","col_3":"0.0025"},"row_9":{"col_1":"0.01<br>","col_2":"0.0009<br>","col_3":"0.0022"},"row_10":{"col_1":"0.005","col_2":"0.0007<br>","col_3":"0.0021"},"row_11":{"col_1":"0.03","col_2":"0.00064","col_3":"0.0021"},"row_12":{"col_1":"0.002<br>","col_2":"0.00062","col_3":"0.0021"},"row_13":{"col_1":"","col_2":"","col_3":""}}
Reflection Factor in coaxial line
the expanded uncertainties given are dimensionless
measured temperature :(23±1)C°
measured relative humidity :Between 30% and 50%
reflectometer compensate
VM3
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.1.a
CMC ID : AFRIMETS-EM-TN-00000LJF-1
 
Frequency , Frequency : 15 GHz to 20 GHz
Frequency counter
Absolute expanded uncertainty : 3 Hz to 4 Hz
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in Hz"},"row_2":{"col_1":"0.01 Hz","col_2":"3.1E-07"},"row_3":{"col_1":"0.1 Hz","col_2":"3.1E-06"},"row_4":{"col_1":"1 Hz","col_2":"3.1E-06"},"row_5":{"col_1":"10 Hz","col_2":"3.1E-06"},"row_6":{"col_1":"100 Hz","col_2":"3.1E-06"},"row_7":{"col_1":"1000 Hz","col_2":"3.1E-06"},"row_8":{"col_1":"1E+04 Hz","col_2":"3.1E-06"},"row_9":{"col_1":"1E+05 Hz","col_2":"3.1E-06"},"row_10":{"col_1":"1E+06 Hz","col_2":"3.1E-06"},"row_11":{"col_1":"1E+07 Hz","col_2":"3.1E-05"},"row_12":{"col_1":"1E+08 Hz","col_2":"3.1E-04"},"row_13":{"col_1":"1E+09 Hz","col_2":"3.1E-03"},"row_14":{"col_1":"1E+10 Hz","col_2":"3.1E-02"},"row_15":{"col_1":"1.5E+10 Hz","col_2":"4.7E-02"},"row_16":{"col_1":"1.5E+10 Hz","col_2":"3"},"row_17":{"col_1":"1.6E+10 Hz","col_2":"3"},"row_18":{"col_1":"1.7E+10 Hz","col_2":"3"},"row_19":{"col_1":"1.8E+10 Hz","col_2":"4"},"row_20":{"col_1":"1.9E+10 Hz","col_2":"4"},"row_21":{"col_1":"2.0E+10 Hz","col_2":"4"}}
Direct frequency mesurement
Averaging time : 1 s
Number of measurements : 30
Amplitude : >= 0 dBm in 50 ohms
Approved on 27 March 2017
Institute service identifier : DEF-NAT 2.3.1
CMC ID : AFRIMETS-TF-TN-000008LT-1
 
Radio frequency measurements , RF attenuation, in coaxials (values in dB) : 0 dB to 80 dB
passive device (piston attenuator)
Absolute expanded uncertainty : 2.6E-2 dB to 0.2 dB
{"row_1":{"col_1":"Attenuation A<sub>x <strong>(*)</strong></sub><br>","col_2":"Expanded uncertainty (dB)"},"row_2":{"col_1":"0<br>","col_2":"0.026"},"row_3":{"col_1":"1","col_2":"0.028"},"row_4":{"col_1":"2","col_2":"0.028"},"row_5":{"col_1":"3","col_2":"0.028"},"row_6":{"col_1":"4","col_2":"0.028"},"row_7":{"col_1":"5","col_2":"0.028"},"row_8":{"col_1":"6","col_2":"0.029"},"row_9":{"col_1":"7","col_2":"0.029"},"row_10":{"col_1":"8","col_2":"0.029<br>"},"row_11":{"col_1":"9","col_2":"0.029"},"row_12":{"col_1":"10","col_2":"0.029"},"row_13":{"col_1":"15","col_2":"0.030"},"row_14":{"col_1":"20","col_2":"0.032"},"row_15":{"col_1":"25","col_2":"0.035<br>"},"row_16":{"col_1":"30<br>","col_2":"0.037"},"row_17":{"col_1":"35<br>","col_2":"0.039"},"row_18":{"col_1":"40<br>","col_2":"0.042"},"row_19":{"col_1":"45","col_2":"0.045"},"row_20":{"col_1":"50","col_2":"0.18"},"row_21":{"col_1":"55","col_2":"0.18"},"row_22":{"col_1":"60<br>","col_2":"0.19"},"row_23":{"col_1":"65<br>","col_2":"0.19"},"row_24":{"col_1":"70","col_2":"0.19"},"row_25":{"col_1":"75","col_2":"0.19"},"row_26":{"col_1":"80","col_2":"0.20"}}
The expanded uncertainties given in this table are expressed in dB
 -Temperature : (23±1)C°
 -Relative humidity:Between 30% and 50%
(*) Measurement frequency : fixed at 30 MHz.
 
Direct method
VM3 (evanescent wave attenuator)
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.3.c
CMC ID : AFRIMETS-EM-TN-00000LJR-1
 
Radio frequency measurements , Scalar RF attenuation: in waveguide, magnitude : 0 dB to 80 dB
passive devices(rotary vane attenuator)
Absolute expanded uncertainty : 7.5E-2 dB to 0.28 dB
{"row_1":{"col_1":"Frequency(GHz)<br>","col_2":"measurement range (dB)<br>","col_3":"Expanded uncertainty (dB)<br>"},"row_2":{"col_1":"8.2-12.4 GHz","col_2":"[0-10]","col_3":"0.075"},"row_3":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-15]","col_3":"0.076"},"row_4":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-20]","col_3":"0.077"},"row_5":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-35]<br>","col_3":"0.078"},"row_6":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-40]<br>","col_3":"0.08<br>"},"row_7":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-45]<br>","col_3":"0.082"},"row_8":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-50]<br>","col_3":"0.22<br>"},"row_9":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-55]","col_3":"0.22"},"row_10":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-60]","col_3":"0.22<br>"},"row_11":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-65]","col_3":"0.22"},"row_12":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-70]","col_3":"0.22"},"row_13":{"col_1":"8.2-12.4 GHz<br>","col_2":"[0-75]","col_3":"0.22"},"row_14":{"col_1":"8.2-12.4 GHz","col_2":"[0-80]","col_3":"0.28"},"row_15":{"col_1":"","col_2":"","col_3":""},"row_16":{"col_1":"","col_2":"","col_3":""}}
The expanded uncertainties given are expressed in dB
 -Temperature:(23±1)C°
 -Relative humidity: Between 30% and 50%
Γx < 0.07
subtitution at 30 MHz
VM3 (evanescent wave attenuator)
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.4
CMC ID : AFRIMETS-EM-TN-00000LJS-1
 
Frequency , Frequency : 1.00E7 Hz to 1.50E10 Hz
Frequency counter
Absolute expanded uncertainty : 3.1E-5 Hz to 4.7E-2 Hz
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in Hz"},"row_2":{"col_1":"0.01 Hz","col_2":"3.1E-07"},"row_3":{"col_1":"0.1 Hz","col_2":"3.1E-06"},"row_4":{"col_1":"1 Hz","col_2":"3.1E-06"},"row_5":{"col_1":"10 Hz","col_2":"3.1E-06"},"row_6":{"col_1":"100 Hz","col_2":"3.1E-06"},"row_7":{"col_1":"1000 Hz","col_2":"3.1E-06"},"row_8":{"col_1":"1E+04 Hz","col_2":"3.1E-06"},"row_9":{"col_1":"1E+05 Hz","col_2":"3.1E-06"},"row_10":{"col_1":"1E+06 Hz","col_2":"3.1E-06"},"row_11":{"col_1":"1E+07 Hz","col_2":"3.1E-05"},"row_12":{"col_1":"1E+08 Hz","col_2":"3.1E-04"},"row_13":{"col_1":"1E+09 Hz","col_2":"3.1E-03"},"row_14":{"col_1":"1E+10 Hz","col_2":"3.1E-02"},"row_15":{"col_1":"1.5E+10 Hz","col_2":"4.7E-02"},"row_16":{"col_1":"1.5E+10 Hz","col_2":"3"},"row_17":{"col_1":"1.6E+10 Hz","col_2":"3"},"row_18":{"col_1":"1.7E+10 Hz","col_2":"3"},"row_19":{"col_1":"1.8E+10 Hz","col_2":"4"},"row_20":{"col_1":"1.9E+10 Hz","col_2":"4"},"row_21":{"col_1":"2.0E+10 Hz","col_2":"4"}}
Direct frequency mesurement
Averaging time : 100 s
Number of measurements : 30
Amplitude : >= 0 dBm in 50 ohms
Approved on 27 March 2017
Institute service identifier : DEF-NAT 2.3.1
CMC ID : AFRIMETS-TF-TN-000008LS-1
 
Time interval , Time interval : 1.00E-9 s to 1.00E5 s
Time difference meter
Absolute expanded uncertainty
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in s"},"row_2":{"col_1":"1.00E-09 s","col_2":"2.00E-09"},"row_3":{"col_1":"1.00E-08 s","col_2":"2.00E-09"},"row_4":{"col_1":"1.00E-07 s","col_2":"2.00E-09"},"row_5":{"col_1":"1.00E-06 s","col_2":"2.00E-09"},"row_6":{"col_1":"1.00E-05 s","col_2":"2.00E-09"},"row_7":{"col_1":"1.00E-04 s","col_2":"2.00E-09"},"row_8":{"col_1":"1.00E-03 s","col_2":"2.00E-09"},"row_9":{"col_1":"1.00E-02 s","col_2":"2.00E-09"},"row_10":{"col_1":"1.00E-01 s","col_2":"2.00E-09"},"row_11":{"col_1":"1 s","col_2":"2.02E-09"},"row_12":{"col_1":"10 s","col_2":"2.20E-09"},"row_13":{"col_1":"100 s","col_2":"4.00E-09"},"row_14":{"col_1":"1000 s","col_2":"2.20E-08"},"row_15":{"col_1":"10000 s","col_2":"2.02E-07"},"row_16":{"col_1":"100000 s","col_2":"2.00E-06"}}
2E-11t + 2E-09

t time interval in s, values range from 2E-09 s to 2E-06 s

The uncertainty is expressed in s

Time interval measurement
Amplitude : >= 1 V in 50 ohms
Slew rate : > 1 V/ns Number of measurements : 10
Approved on 27 March 2017
Institute service identifier : DEF-NAT 3.4.3
CMC ID : AFRIMETS-TF-TN-000008LW-1
 
Time interval , Time interval : 1.00E-8 s to 1000 s
Pulse width meter
Absolute expanded uncertainty
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in s"},"row_2":{"col_1":"1.00E-08 s","col_2":"2.00E-09"},"row_3":{"col_1":"1.00E-07 s","col_2":"2.00E-09"},"row_4":{"col_1":"1.00E-06 s","col_2":"2.00E-09"},"row_5":{"col_1":"1.00E-05 s","col_2":"2.00E-09"},"row_6":{"col_1":"1.00E-04 s","col_2":"2.00E-09"},"row_7":{"col_1":"1.00E-03 s","col_2":"2.00E-09"},"row_8":{"col_1":"1.00E-02 s","col_2":"2.00E-09"},"row_9":{"col_1":"1.00E-01 s","col_2":"2.00E-09"},"row_10":{"col_1":"1 s","col_2":"2.02E-09"},"row_11":{"col_1":"10 s","col_2":"2.20E-09"},"row_12":{"col_1":"100 s","col_2":"4.00E-09"},"row_13":{"col_1":"1000 s","col_2":"2.20E-08"}}
2E-11t + 2E-09

t pulse width in s, values range from 2E-09 s to 2.2E-08 s

The uncertainty is expressed in s

Time interval measurement
Amplitude : >= 1 V in 50 hms
Slew rate : > 1 V/ns Number of measurements : 10
Approved on 27 March 2017
Institute service identifier : DEF-NAT 3.4.2
CMC ID : AFRIMETS-TF-TN-000008LV-1
 
Radio frequency measurements , Scalar RF attenuation in coaxial line : 0 dB to 90 dB
Passive devices(variable attenuator)
Absolute expanded uncertainty : 6.0E-2 dB to 0.38 dB
{"row_1":{"col_1":"Frequency (GHz)<br>","col_2":"Measured range (dB)","col_3":"Expanded uncertainty (dB)<br>"},"row_2":{"col_1":"0.01-12.4 GHz<br>","col_2":"[0-10 dB]","col_3":"(0.06+0.58<em> Γx</em>)"},"row_3":{"col_1":"0.01-12.4 GHz","col_2":"[0-20 dB]","col_3":"(0.06+0.57 <em>Γx</em>)"},"row_4":{"col_1":"0.01-12.4 GHz","col_2":"[0-30 dB]","col_3":"(0.06+0.57 <em>Γx</em>)<br>"},"row_5":{"col_1":"0.01-12.4 GHz","col_2":"[0-40 dB]","col_3":"(0.06+0.56 <em>Γx</em>)"},"row_6":{"col_1":"0.01-12.4 GHz","col_2":"[0-50 dB]<br>","col_3":"[0.29+0.25 <em>Γx</em>]"},"row_7":{"col_1":"0.01-12.4 GHz<br>","col_2":"[0-60 dB]<br>","col_3":"[0.29+0.25 <em>Γx</em>]<br>"},"row_8":{"col_1":"0.01-12.4 GHz","col_2":"[0-70 dB]<br>","col_3":"[0.29+0.25 <em>Γx</em>]"},"row_9":{"col_1":"0.01-12.4 GHz","col_2":"[0-80 dB]","col_3":"[0.34+0.22 <em>Γx</em>]"},"row_10":{"col_1":"0.01-12.4 GHz<br>","col_2":"[0-90 dB]","col_3":"[0.34+0.22 <em>Γx</em>]"}}
The expanded uncertainties given are expressed in dB
 -Temperature: (23±1)C°
 -Relative humidity:Between 30% and 50%
 -Γx<= 0.3
subtitution at 30MHz
VM3
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.3.b
CMC ID : AFRIMETS-EM-TN-00000LJN-1
 
Radio frequency measurements , Reflection coefficient : 1.00E-3 to 0.5
Passive devices
Absolute expanded uncertainty : 6.1E-3 to 1.9E-2
{"row_1":{"col_1":"Γ<sub>x</sub>","col_2":"Expanded uncertainty"},"row_2":{"col_1":"0.5","col_2":"1.9E-2"},"row_3":{"col_1":"0.3","col_2":"1.3E-2"},"row_4":{"col_1":"0.2","col_2":"1.1E-2"},"row_5":{"col_1":"0.1","col_2":"9E-3"},"row_6":{"col_1":"0.05<br>","col_2":"6.7E-3"},"row_7":{"col_1":"0.03<br>","col_2":"6.4E-3"},"row_8":{"col_1":"0.02<br>","col_2":"6.2E-3"},"row_9":{"col_1":"0.01<br>","col_2":"6.1E-3"},"row_10":{"col_1":"0.005<br>","col_2":"6.1E-3"},"row_11":{"col_1":"0.003<br>","col_2":"6.1E-3"},"row_12":{"col_1":"0.002<br>","col_2":"6.1E-1"},"row_13":{"col_1":"0.001<br>","col_2":"6.1E-3"}}
Measurement Frequency from 10 MHz to 100 MHz
ambiant condition:
- T° (23+/-1)°C,  
- Humidity between 30% and 50%
Spectrum analyser
VM3
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.1.b
CMC ID : AFRIMETS-EM-TN-00000LSX-1
 
DC resistance , DC resistance sources: low values : 0.1 Ω to 1 Ω
Fixed resistor & resistance box
Relative expanded uncertainty : 3 µΩ/Ω to 3.3 µΩ/Ω
{"row_1":{"col_1":"0.1Ω<br>","col_2":"3.3"},"row_2":{"col_1":"1Ω","col_2":"3.0"},"row_3":{"col_1":"0.1 &Omega; to 1 &Omega;","col_2":"3.3<br>"}}
comparison to reference resistance with DC resistance bridge
standard resistance LN4210
Approved on 02 May 2023
Institute service identifier : Def-Nat 2.1.1
CMC ID : AFRIMETS-EM-TN-00000O01-1
 
DC resistance , DC Resistance (Intermediate values from 1 ohm up to 10 ohm) : 1 Ω to 10 Ω
Fixed resistor & resistance box
Relative expanded uncertainty : 3 µΩ/Ω to 3.8 µΩ/Ω
{"row_1":{"col_1":"1 Ω<br>","col_2":"3.0"},"row_2":{"col_1":"10 Ω","col_2":"3.8"},"row_3":{"col_1":"1 Ω to 10 Ω","col_2":"3.8"}}
comparison to reference resistance with DC resistance bridge
LN 4210 (1 Ohm)
Approved on 19 February 2023
Institute service identifier : Def-Nat 2.1.2
CMC ID : AFRIMETS-EM-TN-00000O0W-1
 
Frequency , Frequency : 0.01 Hz to 1.00E7 Hz
Frequency counter
Absolute expanded uncertainty : 3.1E-7 Hz to 3.1E-5 Hz
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in Hz"},"row_2":{"col_1":"0.01 Hz","col_2":"3.1E-07"},"row_3":{"col_1":"0.1 Hz","col_2":"3.1E-06"},"row_4":{"col_1":"1 Hz","col_2":"3.1E-06"},"row_5":{"col_1":"10 Hz","col_2":"3.1E-06"},"row_6":{"col_1":"100 Hz","col_2":"3.1E-06"},"row_7":{"col_1":"1000 Hz","col_2":"3.1E-06"},"row_8":{"col_1":"1E+04 Hz","col_2":"3.1E-06"},"row_9":{"col_1":"1E+05 Hz","col_2":"3.1E-06"},"row_10":{"col_1":"1E+06 Hz","col_2":"3.1E-06"},"row_11":{"col_1":"1E+07 Hz","col_2":"3.1E-05"},"row_12":{"col_1":"1E+08 Hz","col_2":"3.1E-04"},"row_13":{"col_1":"1E+09 Hz","col_2":"3.1E-03"},"row_14":{"col_1":"1E+10 Hz","col_2":"3.1E-02"},"row_15":{"col_1":"1.5E+10 Hz","col_2":"4.7E-02"},"row_16":{"col_1":"1.5E+10 Hz","col_2":"3"},"row_17":{"col_1":"1.6E+10 Hz","col_2":"3"},"row_18":{"col_1":"1.7E+10 Hz","col_2":"3"},"row_19":{"col_1":"1.8E+10 Hz","col_2":"4"},"row_20":{"col_1":"1.9E+10 Hz","col_2":"4"},"row_21":{"col_1":"2.0E+10 Hz","col_2":"4"}}
Direct frequency mesurement
Averaging time : 100 s
Number of measurements : 30
Amplitude : >= 1 Vrms in 50 ohms
Approved on 27 March 2017
Institute service identifier : DEF-NAT 2.3.1
CMC ID : AFRIMETS-TF-TN-000008LR-1
 
DC voltage (up to 1100 V) , DC voltage sources: low value ranges : 1.00E-5 V to 10 V
voltage source, multifunction calibrator
Absolute expanded uncertainty : 1.7E-6 V to 3.8E-5 V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / V"},"row_2":{"col_1":"0.01 mV to 200 mV","col_2":"(1.2E-06 <i>U</i> +1.7E-06)"},"row_3":{"col_1":"0.2 V to 2 V","col_2":"(1.2E-06 <i>U</i> + 1.8E-06)"},"row_4":{"col_1":"2 V to 10 V","col_2":"(3.6E-06 <i>U</i> + 1.7E-06)"}}
U is given in V
Comparison to a voltage reference via a DC comparator with a resistive divider
Temperature : (23 ± 1)°C
Approved on 22 November 2016
Institute service identifier : DEF-NAT 1.1.2
CMC ID : AFRIMETS-EM-TN-00000870-1
 
Radio frequency measurements , RF attenuation, in coaxials (values in dB) : 0 dB to 90 dB
passive devices: fixed attenuator
Absolute expanded uncertainty : 7.0E-2 dB to 0.32 dB
{"row_1":{"col_1":"frequency (GHz)<br>","col_2":"measurement range(dB)<br>\nrange:[0-90dB]","col_3":"expanded uncertainty(dB)"},"row_2":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"0","col_3":"(0.07+0.29 <em>Γx</em>)"},"row_3":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"3","col_3":"(0.07+0.30<em contenteditable=\"true\"> Γx</em>)"},"row_4":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"6","col_3":"(0.07+0.29 <em>Γx)</em>"},"row_5":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"10","col_3":"(0.07+0.29 <em>Γx</em>)"},"row_6":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"20","col_3":"(0.07+0.29 <em>Γx</em>)"},"row_7":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"30","col_3":"(0.07+0.29 <em>Γx</em>)"},"row_8":{"col_1":"[0.01-12.4 GHz]","col_2":"40","col_3":"(0.07+0.28 <em contenteditable=\"true\">Γx</em>)<br>"},"row_9":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"50","col_3":"(0.23+0.12 <em>Γx</em>)"},"row_10":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"60","col_3":"(0.23+0.12<em> Γx</em>)"},"row_11":{"col_1":"[0.01-12.4 GHz]<br>","col_2":"70","col_3":"(0.23+0.12 <em>Γx</em>)<br>"},"row_12":{"col_1":"[0.01-12.4 GHz]","col_2":"80","col_3":"(0.24+0.35 <em>Γx</em>)"},"row_13":{"col_1":"[0.01-12.4 GHz]","col_2":"90","col_3":"(0.25+0.35 <em>Γx</em>)"}}
The expanded uncertainties given in this table are expressed in dB
Γx<=0.2
connetctor type N
measured temperature:(23±1) C°
measured relative humidity: Between 30% and 50%
(0.07+0.29ΓX) to (0.25+0.35Γx) the expanded uncertainties given are expressed in dB
Γx<=0.2
subtitution at 30 MHz
VM3 (evanescent wave attenuator)
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.3.a
CMC ID : AFRIMETS-EM-TN-00000LJM-1
 
Radio frequency measurements , Reflection coefficient: in waveguide magnitude : 1.00E-3 to 0.5
Passive devices
Absolute expanded uncertainty : 1.1E-3 to 3.4E-2
{"row_1":{"col_1":"Γ<sub>x</sub>","col_2":"8.2 GHz to 12.4 GHz"},"row_2":{"col_1":"0.5","col_2":"0.034"},"row_3":{"col_1":"0.3","col_2":"0.021"},"row_4":{"col_1":"0.2<br>","col_2":"0.014"},"row_5":{"col_1":"0.1","col_2":"0.007"},"row_6":{"col_1":"0.05<br>","col_2":"0.0036<br>"},"row_7":{"col_1":"0.03","col_2":"0.0023"},"row_8":{"col_1":"0.02<br>","col_2":"0.0017"},"row_9":{"col_1":"0.01<br>","col_2":"0.0013"},"row_10":{"col_1":"0.005<br>","col_2":"0.0011<br>"},"row_11":{"col_1":"0.003","col_2":"0.0011"},"row_12":{"col_1":"0.002<br>","col_2":"0.0011"},"row_13":{"col_1":"0.001<br>","col_2":"0.0011"}}
the expanded uncertainties given are dimensionless
measured temperature :(23±1) C°
measured relative humidity : Between 30% and 50%
reflectometer compensate
VM3(evanescent wave attenuator)
Approved on 15 June 2021
Institute service identifier : DEFNAT 11.2.2
CMC ID : AFRIMETS-EM-TN-00000LJL-1
 
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 1.00E-3 V to 1000 V
DC voltmeter, multimeter, multifunction transfer standard
Absolute expanded uncertainty : 1.7E-6 V to 6.8E-3 V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / V"},"row_2":{"col_1":"1 mV to 200 mV","col_2":"(1.2E-06 <i>U</i>+ 1.7E-06)"},"row_3":{"col_1":"0.2 V to 2 V","col_2":"(1.2E-06 <i>U</i> + 1.8E-06)"},"row_4":{"col_1":"2 V to 10 V","col_2":"(3.6E-06 <i>U</i> + 1.7E-06)"},"row_5":{"col_1":"10 V to 100 V","col_2":"(4.8E-06 <i>U</i> + 1.7E-06)"},"row_6":{"col_1":"100 V to 1000 V","col_2":"(6.8E-06 <i>U</i> + 2.2E-06)"}}
U is given in V
Direct measurement via a standard source
Temperature : (23 ± 1)°C
Approved on 22 November 2016
Institute service identifier : DEF-NAT 1.2.2
CMC ID : AFRIMETS-EM-TN-00000872-1
 
DC voltage (up to 1100 V) , DC voltage sources: single values : 1 V to 10 V
Standard cell, solid state voltage standard
Absolute expanded uncertainty : 0.1 µV to 0.5 µV
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / µV"},"row_2":{"col_1":"1 V","col_2":"0.1"},"row_3":{"col_1":"1.018 V","col_2":"0.1"},"row_4":{"col_1":"10 V","col_2":"0.5"}}
Direct comparison with JAVS, Differential method
Temperature : (23 ± 1)°C
Approved on 22 November 2016
Institute service identifier : DEF-NAT 1.1.1
CMC ID : AFRIMETS-EM-TN-0000086Z-1
 
Frequency , Frequency : 1.00E7 Hz to 1.50E10 Hz
General frequency source
Absolute expanded uncertainty : 3.1E-5 Hz to 4.7E-2 Hz
{"row_1":{"col_1":"","col_2":"Absolute expanded uncertainty expressed in Hz"},"row_2":{"col_1":"0.01 Hz","col_2":"3.1E-07"},"row_3":{"col_1":"0.1 Hz","col_2":"3.1E-06"},"row_4":{"col_1":"1 Hz","col_2":"3.1E-06"},"row_5":{"col_1":"10 Hz","col_2":"3.1E-06"},"row_6":{"col_1":"100 Hz","col_2":"3.1E-06"},"row_7":{"col_1":"1000 Hz","col_2":"3.1E-06"},"row_8":{"col_1":"1E+04 Hz","col_2":"3.1E-06"},"row_9":{"col_1":"1E+05 Hz","col_2":"3.1E-06"},"row_10":{"col_1":"1E+06 Hz","col_2":"3.1E-06"},"row_11":{"col_1":"1E+07 Hz","col_2":"3.1E-05"},"row_12":{"col_1":"1E+08 Hz","col_2":"3.1E-04"},"row_13":{"col_1":"1E+09 Hz","col_2":"3.1E-03"},"row_14":{"col_1":"1E+10 Hz","col_2":"3.1E-02"},"row_15":{"col_1":"1.5E+10 Hz","col_2":"4.7E-02"},"row_16":{"col_1":"1.5E+10 Hz","col_2":"3"},"row_17":{"col_1":"1.6E+10 Hz","col_2":"3"},"row_18":{"col_1":"1.7E+10 Hz","col_2":"3"},"row_19":{"col_1":"1.8E+10 Hz","col_2":"4"},"row_20":{"col_1":"1.9E+10 Hz","col_2":"4"},"row_21":{"col_1":"2.0E+10 Hz","col_2":"4"}}
Direct frequency mesurement
Averaging time : 100 s
Number of measurements : 30
Amplitude : >= 0 dBm in 50 ohms
Approved on 27 March 2017
Institute service identifier : DEF-NAT 2.2.1.a
CMC ID : AFRIMETS-TF-TN-000008LP-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.