Results for: azerbaijan
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
35 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Ionizing radiation
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Azerbaijan, AzMI (Azerbaijan Institute of Metrology)
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 60 °C to 300 °C
Liquid-in-glass thermometers, total immersion 0.1 °C
Absolute expanded uncertainty : 5.0E-2 K
Comparison method
Stirred liquid bath : silicon oil
Approved on 31 March 2020
Institute service identifier : AzMI/15
CMC ID : COOMET-T-AZ-00000KG4-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 300 °C
Base metal
thermocouples
Absolute expanded uncertainty : 0.7 K
Comparison method
Stirred liquid bath : ethanol, water or silicon oil
Approved on 31 March 2020
Institute service identifier : AzMI/11
CMC ID : COOMET-T-AZ-00000KG0-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 300 °C
Digital thermometer Thermocouples
Absolute expanded uncertainty : 0.7 °C
Comparison method
Stirred liquid bath : ethanol, water or oil
Approved on 31 March 2020
Institute service identifier : AzMI/23
CMC ID : COOMET-T-AZ-00000KGC-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 80 °C
Digital thermometer thermistor
Absolute expanded uncertainty : 4.0E-2 K
Comparison method
Thermostat : water
Approved on 31 March 2020
Institute service identifier : AzMI/21
CMC ID : COOMET-T-AZ-00000KGA-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 300 °C
Digital thermometer IPRT
Absolute expanded uncertainty : 5.0E-2 K
Comparison method
Thermostat : oil
Approved on 31 March 2020
Institute service identifier : AzMI/19
CMC ID : COOMET-T-AZ-00000KG8-1
 
Mass , Mass : 10 g to 100 g
Mass standards
Absolute expanded uncertainty : 2.0E1 µg to 5.0E1 µg
Comparison in air
Temperature : 18.0 °C to 23.0 °C
Relative humidity : 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 25 October 2020
Institute service identifier : 03-AzMI-04L
CMC ID : COOMET-M-AZ-00000M7B-1
 
Mass , Mass : 0.1 kg to 1 kg
Mass standards
Absolute expanded uncertainty : 5.0E-2 mg to 0.5 mg
Comparison in air
Temperature : 18.0 °C to 23.0 °C
Relative humidity : 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 25 October 2020
Institute service identifier : 03-AzMI-04L
CMC ID : COOMET-M-AZ-00000M7C-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 0 °C
Industrial Platinum
Resistance
thermometers
Absolute expanded uncertainty : 1.2E-2 K
Direct comparison
Thermostat : ethanol
Approved on 31 March 2020
Institute service identifier : AzMI/1
CMC ID : COOMET-T-AZ-00000KFQ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 80 °C
Industrial Platinum
Resistance
thermometers
Absolute expanded uncertainty : 1.4E-2 K
Direct comparison
Thermostat : water
Approved on 31 March 2020
Institute service identifier : AzMI/3
CMC ID : COOMET-T-AZ-00000KFS-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Noble metal
thermocouples, type S and R
Absolute expanded uncertainty : 0.4 K
Comparison method
Thermostat : ethanol
Approved on 31 March 2020
Institute service identifier : AzMI/9
CMC ID : COOMET-T-AZ-00000KFY-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Thermistors
Absolute expanded uncertainty : 4.0E-2 K
Comparison method
Thermostat : ethanol
Approved on 31 March 2020
Institute service identifier : AzMI/6
CMC ID : COOMET-T-AZ-00000KFV-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 420 °C
Noble metal
thermocouples, type S and R
Absolute expanded uncertainty : 0.6 K
Comparison method
Approved on 31 March 2020
Institute service identifier : AzMI/10
CMC ID : COOMET-T-AZ-00000KFZ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 300 °C to 420 °C
Base metal
thermocouples
Absolute expanded uncertainty : 0.8 K
Comparison method
Approved on 31 March 2020
Institute service identifier : AzMI/12
CMC ID : COOMET-T-AZ-00000KG1-1
 
Ionizing radiation
Kerma/rate , Protection level ionization chambers : 12 mGy/h to 120 mGy/h
Relative expanded uncertainty 1.6 % to 1.9 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, ISO 4037:2019, Narrow Series, 40 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : IAEA
Approved on 24 June 2024
Institute service identifier : COO-RAD-AzMI-1003
CMC ID : COOMET-RI-AZ-00000PVA-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionization chambers : 1.2 Gy/h to 6.9 Gy/h
Relative expanded uncertainty 1.7 % to 1.9 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, IEC 61267, RQR series, 50 kV to 150 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : IAEA
Approved on 24 June 2024
Institute service identifier : COO-RAD-AzMI-1002
CMC ID : COOMET-RI-AZ-00000PV9-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 300 °C
Liquid-in-glass thermometer; graduation ≥ 0.2 °C
Absolute expanded uncertainty : 7.0E-2 K to 1.2 K
Comparison method
Stirred liquid bath : ethanol, water or silicon oil
Approved on 31 March 2020
Institute service identifier : AzMI/16
CMC ID : COOMET-T-AZ-00000KG5-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 100 °C
Digital thermometer thermistor
Absolute expanded uncertainty : 5.0E-2 K
Comparison method
Stirred liquid bath :  water or oil
Approved on 31 March 2020
Institute service identifier : AzMI/22
CMC ID : COOMET-T-AZ-00000KGB-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 300 °C
Industrial Platinum
Resistance
thermometers
Absolute expanded uncertainty : 5.0E-2 K
Direct comparison
Thermostat : silicon oil
Approved on 31 March 2020
Institute service identifier : AzMI/4
CMC ID : COOMET-T-AZ-00000KFT-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Industrial Platinum
Resistance
thermometers
Absolute expanded uncertainty : 4.0E-2 K
Direct comparison
Thermostat : ice bath
Approved on 31 March 2020
Institute service identifier : AzMI/2
CMC ID : COOMET-T-AZ-00000KFR-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 10 °C
Liquid-in-glass thermometers, total immersion 0.1 °C
Absolute expanded uncertainty : 4.0E-2 K
Comparison method
Stirred liquid bath : ethanol
Approved on 31 March 2020
Institute service identifier : AzMI/13
CMC ID : COOMET-T-AZ-00000KG2-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.