Results for: moldova
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
84 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Moldova, Republic of, NMI (MD) (The National Metrology Institute of the Republic of Moldova)
Items for defining ITS-90 , Temperature : 0.01 °C to 660.323 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.3 mK to 3.6 mK
Calibration at fixed points
Temperature-controlled furnace : Heat-pipe
furnace
Approved on 31 March 2020
Institute service identifier : 340041
CMC ID : EURAMET-T-MD-00000KHV-1
 
Items for defining ITS-90 , Temperature : 660.323 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 3.6 mK
Calibration at aluminium fixed point
Temperature-controlled furnace : Heat-pipe
furnace
Approved on 31 March 2020
Institute service identifier : 340040
CMC ID : EURAMET-T-MD-00000KHQ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 156.5985 °C
Indium cell
Absolute expanded uncertainty : 1.2 mK
Direct comparison
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340038
CMC ID : EURAMET-T-MD-000006CS-2
 
Items for defining ITS-90 , Temperature : 0.01 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.3 mK
Water triple point
Thermostat : ice bath
Approved on 31 March 2020
Institute service identifier : 340035
CMC ID : EURAMET-T-MD-000006CV-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 300 °C
Noble metal thermocouple, type S, R and B
Absolute expanded uncertainty : 0.4 °C
Comparison method
Stirred liquid bath : ethanol, water or silicon oil
Approved on 31 March 2020
Institute service identifier : 340013
CMC ID : EURAMET-T-MD-00000KHZ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 80 °C to 300 °C
Industrial Platinum Resistance Thermometer
Absolute expanded uncertainty : 3.0E-2 K
Direct comparison
Thermostat : silicon oil
Approved on 31 March 2020
Institute service identifier : 340011
CMC ID : EURAMET-T-MD-000006D2-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Industrial Platinum Resistance Thermometer
Absolute expanded uncertainty : 6.0E-3 K
Direct comparison
Thermostat : ethanol
Approved on 31 March 2020
Institute service identifier : 340011
CMC ID : EURAMET-T-MD-000006D0-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 80 °C
Digital thermometer thermistor
Absolute expanded uncertainty : 4.0E-2 K
Comparison method
Thermostat : water
Approved on 31 March 2020
Institute service identifier : 340019
CMC ID : EURAMET-T-MD-000006DI-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -80 °C to 10 °C
Digital thermometer IPRT
Absolute expanded uncertainty : 4.0E-2 K
Comparison method
Cryostat : ethanol
Approved on 31 March 2020
Institute service identifier : 340019
CMC ID : EURAMET-T-MD-000006DF-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 150 °C
Thermistor
Absolute expanded uncertainty : 5.0E-2 K
Comparison method
Thermostat : silicon oil
Approved on 31 March 2020
Institute service identifier : 340042
CMC ID : EURAMET-T-MD-000006D5-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C to 660 °C
Noble metal thermocouple, type S, R and B
Absolute expanded uncertainty : 0.4 °C
Calibration at fixed points
Approved on 31 March 2020
Institute service identifier : 340045
CMC ID : EURAMET-T-MD-00000KHY-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 300 °C to 660 °C
Digital thermometer IPRT
Absolute expanded uncertainty : 0.3 K to 0.7 K
Comparison method
Approved on 31 March 2020
Institute service identifier : 340019
CMC ID : EURAMET-T-MD-00000KIA-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 29.7646 °C
Thermocouple S and R
Absolute expanded uncertainty : 0.4 °C
Calibration at gallium fixed point
Approved on 31 March 2020
Institute service identifier : 340043
CMC ID : EURAMET-T-MD-000006D7-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 156.5985 °C
Digital thermometer thermocouple
Absolute expanded uncertainty : 0.4 K
Calibration at indium fixed point
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340047
CMC ID : EURAMET-T-MD-000006CJ-2
 
Fluid flow , Volume of liquid : 2 L to 1000 L
Proving tanks
Relative expanded uncertainty : 2.1E-2 %
Volumetric
Liquid  : water
Reference temperature : 20 0C
Approved on 20 September 2023
Institute service identifier : 362005
CMC ID : EURAMET-M-MD-00000OJH-1
 
Items for defining ITS-90 , Temperature : 0.01 °C to 419.527 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.3 mK to 2.7 mK
Calibration at fixed points
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340010
CMC ID : EURAMET-T-MD-00000KHU-1
 
Items for defining ITS-90 , Temperature : 29.7646 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 0.5 mK
Calibration at gallium fixed point
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340035
CMC ID : EURAMET-T-MD-000006CW-2
 
Items for defining ITS-90 , Temperature : 231.928 °C
Standard Platinum Resistance Thermometer
Absolute expanded uncertainty : 1.5 mK
Calibration at tin fixed point
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340009
CMC ID : EURAMET-T-MD-000006CY-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 156.5985 °C
Thermocouple S and R
Absolute expanded uncertainty : 0.4 °C
Calibration at indium fixed point
Temperature-controlled furnace : 3-zone
Approved on 31 March 2020
Institute service identifier : 340043
CMC ID : EURAMET-T-MD-000006D8-2
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 0 °C
Thermistor
Absolute expanded uncertainty : 6.0E-3 K
Comparison method
Thermostat : ethanol
Approved on 31 March 2020
Institute service identifier : 340042
CMC ID : EURAMET-T-MD-000006D3-2
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.