Results for: portugal flow
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
19 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Portugal, IPQ (Instituto Portugues da Qualidade)
Fluid flow , Volume of liquid : 1 mL to 1.00E4 mL
Glassware equipment; Pipettes, flasks, burettes, cylinders
Relative expanded uncertainty : 1.0E-2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.08, 103.07, 103.06, 103.09
CMC ID : EURAMET-M-PT-00000C9U-2
 
Fluid flow , Volume flowrate (or Mass flowrate); liquid : 0.12 mL/h to 2000 mL/h
Flow meter and flow generator (e.g. coriolis meters, syringe pumps)
Relative expanded uncertainty : 2.5 % to 0.11 %
Gravimetric
Liquid : water
Temperature : ambient
Pressure : up to 3 hPa
Approved on 11 September 2019
Institute service identifier : IPQ/104.01, 104.02, 104.03, 104.61
CMC ID : EURAMET-M-PT-00000C9I-2
 
DC current (up to 100 A) , DC current meters: low values : 1.00E-8 A to 1.00E-4 A
Ammeter, multimeter
Relative expanded uncertainty : 1.5E1 µA/A to 7.5E1 µA/A
{"row_1": {"col_1":"Current", "col_2":"Expanded uncertainty<br>/ (µA/A)"}, "row_2": {"col_1":"10 nA to 100 nA", "col_2":"75"}, "row_3": {"col_1":"100 nA to 1 µA", "col_2":"25"}, "row_4": {"col_1":"1 µA to 10 µA", "col_2":"20"}, "row_5": {"col_1":"10 µA to 100 µA", "col_2":"15"}}
Source characterised using voltage and standard resistor
Approved on 31 March 2022
Institute service identifier : IPQ/403.22
CMC ID : EURAMET-EM-PT-00000MHH-1
 
Fluid flow , Liquid flow : 3.00E-4 mL/h to 0.12 mL/h
Flow generators (e.g. syringe pumps)
Relative expanded uncertainty : 2.7 % to 1.3 %
Interferometric method
Reference temperature : 20 ºC
Liquid : Water
Pressure : up to 3 hPa
Approved on 09 July 2022
Institute service identifier : 104.01, 104.02 and 104.03
CMC ID : EURAMET-M-PT-00000NW9-1
 
DC resistance , DC resistance standards and sources: low values : 1.00E-4 Ω to 1 Ω
Standard resistor
Relative expanded uncertainty : 5 µΩ/Ω to 1.2 µΩ/Ω
{"row_1": {"col_1":"<strong>Resistance<\/strong>", "col_2":"<strong>Expanded uncertainty/(µΩ/Ω)<\/strong>"}, "row_2": {"col_1":"0.1 mΩ to 10 mΩ", "col_2":"5"}, "row_3": {"col_1":"0.1 Ω", "col_2":"2"}, "row_4": {"col_1":"1 Ω", "col_2":"1.2"}, "row_5": {"col_1":"10 kΩ", "col_2":"1.2"}, "row_6": {"col_1":"10 Ω to 100 kΩ", "col_2":"1.5"}, "row_7": {"col_1":"100 kΩ to 1 MΩ", "col_2":"2"}, "row_8": {"col_1":"1 MΩ to 10 MΩ", "col_2":"3"}, "row_9": {"col_1":"10 MΩ to 100 MΩ", "col_2":"7"}, "row_10": {"col_1":"100 MΩ", "col_2":"20"}}
Comparison using DCC bridge
Oil and air bath temperature : 18 °C to 25 °C
Approved on 04 March 2021
Institute service identifier : IPQ/402.11, IPQ/402.12
CMC ID : EURAMET-EM-PT-0000069X-3
 
DC current (up to 100 A) , DC current sources: low values : 1.00E-8 A to 1.00E-4 A
Current generator, calibrator
Relative expanded uncertainty : 1.5E1 µA/A to 7.5E1 µA/A
{"row_1": {"col_1":"Current", "col_2":"Expanded uncertainty<br>/ (µA/A)"}, "row_2": {"col_1":"10 nA to 100 nA", "col_2":"75"}, "row_3": {"col_1":"100 nA to 1 µA", "col_2":"25"}, "row_4": {"col_1":"1 µA to 10 µA", "col_2":"20"}, "row_5": {"col_1":"10 µA to 100 µA", "col_2":"15"}}
Comparison
Approved on 31 March 2022
Institute service identifier : IPQ/403.11
CMC ID : EURAMET-EM-PT-00000MHE-1
 
Fluid flow , Volume of liquid : 1.00E-3 mL to 200 mL
Piston operating apparatus (burettes, dispensers) and syringes
Relative expanded uncertainty : 2.0E-2 % to 1.0E-2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.09, 103.12, 103.04
CMC ID : EURAMET-M-PT-00000C9G-2
 
Fluid flow , Volume of liquid : 1 L to 20 L
Standard test measures and overflow pipettes
Relative expanded uncertainty : 1.0E-2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.21, 103.20, 103.13
CMC ID : EURAMET-M-PT-00000C9D-2
 
Impedance (up to the MHz range) , Capacitance: low loss capacitors : 1 pF to 1000 pF
Standard capacitor (sealed, dry-nitrogen or fused silica dielectric)
Relative expanded uncertainty : 1.0E1 µF/F
Comparison
Frequency : 100 Hz, 400 Hz, 1000 Hz
Approved on 06 August 2013
Institute service identifier : IPQ/404.21
CMC ID : EURAMET-EM-PT-0000069Z-2
 
Fluid flow , Volume of liquid : 20 L to 1500 L
Proving tanks and overflow pipettes
Relative expanded uncertainty : 1.0E-2 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 19 October 2016
Institute service identifier : IPQ/103.21, 103.20 and 103.13
CMC ID : EURAMET-M-PT-00000C9V-1
 
Fluid flow , Volume of liquid : 1 µL to 2.00E4 µL
Micropipettes or piston pipettes
Relative expanded uncertainty : 0.3 % to 0.1 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.02
CMC ID : EURAMET-M-PT-00000C9F-2
 
Fluid flow , Volume of liquid : 1 L to 20 L
Standard test measures
Relative expanded uncertainty : 2.0E-2 %
Volumetric
Liquid : water
Ambient temperature : 10°C to 30 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.21
CMC ID : EURAMET-M-PT-00000C9E-2
 
Fluid flow , Volume of liquid : 20 L to 1.00E4 L
Proving tanks
Relative expanded uncertainty : 2.0E-2 %
Volumetric
Liquid : water
Ambient temperature : 10°C to 30 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.21
CMC ID : EURAMET-M-PT-00000C9C-2
 
DC voltage (up to 1100 V) , DC voltage sources: low values : 1.00E-3 V to 10 V
Calibrator
Relative expanded uncertainty : 3 µV/V to 5.0E1 µV/V
{"row_1": {"col_1":"<strong>Voltage<\/strong>", "col_2":"<strong>Expanded uncertainty<br>/ (µV/V)<\/strong>"}, "row_2": {"col_1":"1 mV to 2 V", "col_2":"50"}, "row_3": {"col_1":"2 V to 10 V", "col_2":"3"}, "row_4": {"col_1":"10 V to 20 V", "col_2":"3"}, "row_5": {"col_1":"20 V to 1000 V", "col_2":"5"}}
Comparison to a reference with a resistive divider
Approved on 06 August 2013
Institute service identifier : IPQ/401.12
CMC ID : EURAMET-EM-PT-0000069T-2
 
DC resistance , DC resistance meters: low values : 0.01 Ω to 1 Ω
Resistance meter
Relative expanded uncertainty : 7 µΩ/Ω to 2 µΩ/Ω
{"row_1": {"col_1":"Resistance", "col_2":"Expanded uncertainty<br>/ (µΩ/Ω)"}, "row_2": {"col_1":"10 mΩ", "col_2":"7"}, "row_3": {"col_1":"100 mΩ", "col_2":"5"}, "row_4": {"col_1":"1 Ω", "col_2":"1.5"}, "row_5": {"col_1":"10 Ω to 100 kΩ", "col_2":"2"}, "row_6": {"col_1":"1 MΩ", "col_2":"5"}, "row_7": {"col_1":"10 MΩ", "col_2":"7"}, "row_8": {"col_1":"100 MΩ", "col_2":"25"}}
Direct measurement
Air temperature : 23 °C
Approved on 05 April 2021
Institute service identifier : IPQ/409.52
CMC ID : EURAMET-EM-PT-00000MHL-1
 
Fluid flow , Volume of liquid : 0.1 µL to 1000 µL
Micropipettes or piston pipettes
Relative expanded uncertainty : 2.7 % to 0.4 %
Photometric
Liquid : Aqueous solutions
Approved on 11 September 2019
Institute service identifier : IPQ/103.02
CMC ID : EURAMET-M-PT-00000C9J-2
 
Fluid flow , Volume of liquid : 1 mL to 100 mL
Pycnometers
Relative expanded uncertainty : 3.0E-3 %
Gravimetric
Liquid : water
Reference temperature : 20 °C
Approved on 11 September 2019
Institute service identifier : IPQ/103.10
CMC ID : EURAMET-M-PT-00000C9T-2
 
DC current (up to 100 A) , DC current meters: low values : 1.00E-13 A to 1.00E-9 A
Picoammeter, electrometer
Relative expanded uncertainty : 1.5E2 µA/A to 2.0E3 µA/A
{"row_1": {"col_1":"-", "col_2":"Expanded uncertainty<br>/ (µA/A)"}, "row_2": {"col_1":"1E-13", "col_2":"2000"}, "row_3": {"col_1":"1E-12", "col_2":"500"}, "row_4": {"col_1":"1E-11", "col_2":"200"}, "row_5": {"col_1":"1E-10", "col_2":"150"}, "row_6": {"col_1":"1E-9", "col_2":"150"}}
Charging of a capacitor
Approved on 31 March 2022
Institute service identifier : IPQ/403.21
CMC ID : EURAMET-EM-PT-00000MHG-1
 
Fluid flow , Liquid flow : 1.20E-3 mL/h to 0.12 mL/h
Flowmeter
Relative expanded uncertainty : 5.2 % to 2.5 %
Interferometric method
Reference Temperature : 20 ºC
Liquid : Water
Pressure : up to 3 hPa
Approved on 09 July 2022
Institute service identifier : 104.61
CMC ID : EURAMET-M-PT-00000NW8-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.