Results for: russia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
1759 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Chemical material
Chemical Analyte
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Russian Federation, VNIIFTRI (Institute of Physical Technical and Radiotechnical Measurements, Rosstandart)
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
water 3.8 to 4.2 4.6E-3 3.8 to 4.2 6.0E-3 to 1.0E-2
  • Mechanism for measurement service delivery : CRM: primary buffer solution (potassium hydrophtalate), measurement of solution
  • Temperature range 15 °C to 37 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention. The values are given for a temperature of 25°C.
  • Approved on 30 June 2017
  • Institute service identifier : 630-3
  • CMC ID : COOMET-QM-RU-0000015I-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 6.84 to 6.98 4.0E-3 6.861 to 6.869 4.0E-3
  • Mechanism for measurement service delivery : CRM 630-04a/b: disodium hydrogen phosphate + potassium dihydrogen phosphate. Calibration
  • Temperature range 0 °C to 60 °C. Data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention
  • Approved on 06 December 2011
  • Institute service identifier : 630-4
  • CMC ID : COOMET-QM-RU-0000015F-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 9.5 to 10.5 3.9E-3
  • Mechanism for measurement service delivery : Calibration
  • The all values are given for a temperature of 25°C.
    Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
  • Approved on 03 May 2021
  • Institute service identifier : 630-06
  • CMC ID : COOMET-QM-RU-00000M37-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solution (KCl or NaCl) 0.15 to 1.5 5.0E-2
  • Mechanism for measurement service delivery : Calibration
  • Temperature range is from 15 °C to 30 °C. The data is given for 25 °C.
  • Approved on 03 May 2021
  • Institute service identifier : 610-19
  • CMC ID : COOMET-QM-RU-00000M61-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 8.95 to 9.47 3.6E-3 9.176 to 9.184 8.0E-3
  • Mechanism for measurement service delivery : CRM 630-05: disodium tetraborate. Calibration
  • The temperature range 5°C to 50°C.
    Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention.
     
  • Approved on 14 September 2022
  • Institute service identifier : 630-5
  • CMC ID : COOMET-QM-RU-0000015H-2
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 3.55 to 3.56 4.0E-3 3.553 to 3.561 4.0E-3
  • Mechanism for measurement service delivery : CRM 630-02: potassium hydrogen tartrate. Calibration
  • Temperature range 0 °C to 60 °C. Data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention
  • Approved on 06 December 2011
  • Institute service identifier : 630-2
  • CMC ID : COOMET-QM-RU-0000015D-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 4 to 4.08 4.0E-3 4.001 to 4.009 4.0E-3
  • Mechanism for measurement service delivery : CRM 630-03: potassium hydrogen phthalate. Calibration
  • Temperature range 0 °C to 60 °C. Data given for 25 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention
  • Approved on 06 December 2011
  • Institute service identifier : 630-3
  • CMC ID : COOMET-QM-RU-0000015E-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
Electrolytic conductivity in S/m Relative expanded uncertainty in % Electrolytic conductivity in S/m Relative expanded uncertainty in %
aqueous solutions, multi-component aqueous salt solutions (sea water) 1.00E-3 to 9.999 0.3 to 5.0E-2 1.00E-3 to 9.999 0.3 to 5.0E-2
  • Mechanism for measurement service delivery : Calibration, CRM (aqueous solution of KCl)
  • Temperature range is from 0 °C to 90 °C. Data is given for 25 °C
  • Approved on 06 December 2011
  • Institute service identifier : 610-18
  • CMC ID : COOMET-QM-RU-000003BV-1
     
Matrix or material Dissemination range of measurement capability Range of certified values in reference materials
pH in Absolute expanded uncertainty in pH in Absolute expanded uncertainty in
aqueous buffer solution 6.8 to 7.5 6.0E-3 to 8.0E-3 6.86 to 7.41 1.0E-2
  • Mechanism for measurement service delivery : CRM 630-04a/b: disodium hydrogen phosphate + potassium dihydrogen phosphate. Calibration
  • Temperature range 15 °C to 37 °C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention. The values are given for a temperature of 25 °C
  • Approved on 30 June 2016
  • Institute service identifier : b
  • CMC ID : COOMET-QM-RU-0000015G-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in
leather materials arsenic 10 to 100 1 to 7
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 23 October 2019
  • Institute service identifier : 680-5
  • CMC ID : COOMET-QM-RU-00000JZV-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in
leather materials cadmium 10 to 100 0.35 to 2.5
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 23 October 2019
  • Institute service identifier : 680-6
  • CMC ID : COOMET-QM-RU-00000JZW-2
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in
leather materials cobalt 10 to 100 0.3 to 2
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 23 October 2019
  • Institute service identifier : 680-8
  • CMC ID : COOMET-QM-RU-00000JZY-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Absolute expanded uncertainty in µg/kg Mass fraction in Absolute expanded uncertainty in
fresh water copper 1 to 100 0.11 to 8
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 28 June 2018
  • Institute service identifier : 680-1
  • CMC ID : COOMET-QM-RU-000001VO-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Absolute expanded uncertainty in µg/kg Mass fraction in Absolute expanded uncertainty in
fresh water lead 0.1 to 100 1.5E-2 to 1.0E1
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 28 June 2018
  • Institute service identifier : 680-3
  • CMC ID : COOMET-QM-RU-000001VQ-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in
leather materials lead 10 to 100 0.4 to 3
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 23 October 2019
  • Institute service identifier : 680-7
  • CMC ID : COOMET-QM-RU-00000JZX-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Absolute expanded uncertainty in mg/kg Mass fraction in Absolute expanded uncertainty in
fresh water sodium 0.5 to 50 3.5E-2 to 2.5
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 28 June 2018
  • Institute service identifier : 680-4
  • CMC ID : COOMET-QM-RU-000001VR-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Absolute expanded uncertainty in µg/kg Mass fraction in Absolute expanded uncertainty in
fresh water strontium 1 to 100 5.0E-2 to 3.5
  • Mechanism for measurement service delivery : Reference measurement of the sample supplied by the customer
  • Approved on 28 June 2018
  • Institute service identifier : 680-2
  • CMC ID : COOMET-QM-RU-000001VP-1
     
Radio frequency measurements , Scattering parameters: reflection coefficient (Sii) in waveguides, real and imaginary : -1 to 1
Passive device
Absolute expanded uncertainty : 2.0E-3
Network analyserr with RF substitution
Frequency range : 2.14 GHz to 17.44 GHz
Waveguide dimensions : 90/45 mm, 72/34 mm, 48/24 mm, 35/15 mm, 23/10 mm, 16/8 mm
Approved on 21 October 2001
Institute service identifier : VNIIFTRI/328
CMC ID : COOMET-EM-RU-000007HA-1
 
Radio frequency measurements , Scalar RF reflection coefficient and attenuation: attenuation in waveguides : 60 dB to 70 dB
Passive device, amplifier
Absolute expanded uncertainty : 0.25 dB
IF parallel substitution
Frequency range : 37.5 GHz to 178.3 GHz
Reflection coefficient : below or equal to 0.01
Approved on 21 October 2001
Institute service identifier : VNIIFTRI/299
CMC ID : COOMET-EM-RU-000007H9-1
 
Radio frequency measurements , Noise: noise temperature in waveguides : 77 K to 1.00E5 K
Noise source
Relative expanded uncertainty : 5.0E1 mK/K
Comparison with noise temperature standard, radiometer
Frequency : 53.57 GHz to 118.11 GHz
Waveguide dimensions : 3.6/1.8 mm, 2.4/1.2 mm
Approved on 21 October 2001
Institute service identifier : VNIIFTRI/351
CMC ID : COOMET-EM-RU-000007I2-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.