Results for: vugtk
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
8 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Czechia, VUGTK/RIGTC (Research Institute of Geodesy, Topography and Cartography)
Linear dimensions , Line standards : 0.01 m to 3 m
Surveyor's levelling rods: line spacing, L
Absolute expanded uncertainty : 1.0E1 µm to 1.8E1 µm
Q[10 µm, 5.1E-06 L]
Bench and laser-interferometer
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/29
CMC ID : EURAMET-L-CZ-00000AKQ-2
 
Linear dimensions , Line standards : 1.00E-3 m to 30 m
Surveyor invar tapes and wires: line spacing, L
Absolute expanded uncertainty : 6 µm to 1.1E2 µm
Q[6.0 µm, 3.5E-06 L]
30 m bench and laser-interferometer
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/27
CMC ID : EURAMET-L-CZ-00000AKO-2
 
Linear dimensions , Length instruments : 0 km to 10 km
EDM instruments: error of indicated distance, L
Absolute expanded uncertainty : 1.5 mm to 4.3E1 mm
Q[1.5 mm, 4.3E-06 L]
Comparison with geodetic length baseline
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/13
CMC ID : EURAMET-L-CZ-00000AJJ-2
 
Angle , Angle instruments : 0 ° to 360 °
Theodolites, error of indicated angle
Absolute expanded uncertainty : 3.4 "
Asimuthal baseline
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/43
CMC ID : EURAMET-L-CZ-00000AJK-1
 
Linear dimensions , Line standards : 1.00E-3 m to 1000 m
Surveyor tapes and wires: line spacing, L
Absolute expanded uncertainty : 6 µm to 8.2E3 µm
Q[6.0 µm, 8.2E-06 L]
30 m bench and laser-interferometer
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/28
CMC ID : EURAMET-L-CZ-00000AKP-2
 
Various dimensional , Long distance : 0 km to 10 km
Geodetic baseline, interval distances, L
Absolute expanded uncertainty : 0.85 mm to 9.8E1 mm
Q[0.85 mm, 9.8E-06 L]
Laser-interferometer, invar wires, EDM
Approved on 22 March 2005
Institute service identifier : VUGTK/RIGTC/63
CMC ID : EURAMET-L-CZ-00000AJP-2
 
Gravity , Gravity acceleration : 9.8093 m/s2 to 9.80934 m/s2
Absolute gravimeter
Absolute expanded uncertainty : 6.0E-8 m/s2
Comparison against a gravity value of a reference station
Ambient temperature : from 15 ºC to 30 ºC
Approved on 15 September 2020
Institute service identifier : VUGTK/PEC02
CMC ID : EURAMET-M-CZ-00000LPL-1
 
Gravity , Gravity acceleration : 9.75 m/s2 to 9.85 m/s2
 Gravity on (stable) site
Absolute expanded uncertainty : 4.4E-8 m/s2
Absolute measurement
Ambient temperature : from 15 ºC to 30 ºC
Approved on 15 September 2020
Institute service identifier : VUGTK/PEC01
CMC ID : EURAMET-M-CZ-00000LPK-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.