Comparison
Comparison close

12-sided polygon

MEASURAND : Deviation from nominal angle between two faces of the polygon

Degrees of equivalence: Di and expanded uncertainty Ui, both expressed in milliseconds

Angle blocks

MEASURAND : Deviation from nominal angles 5", 5', 30', and 5°

Degrees of equivalence: Di and expanded uncertainty Ui, both expressed in milliseconds

Comparison
Comparison close

12-sided polygon

MEASURAND : Deviation from nominal angle between two faces of the polygon

The tables below give the degrees of equivalence for each participant:

Results are presented under A4 printable format in Summary Results (.PDF file).

Angle blocks

MEASURAND : Deviation from nominal angles 5", 5', 30', and 5°

The tables below give the degrees of equivalence for each participant:

Results are presented under A4 printable format in Summary Results (.PDF file).

Comparison
Comparison close
CC comparison
Linked comparison
Metrology area, Sub-field Length, Dimensional Metrology
Description Angle standards
Time of measurements 2000 - 2002
Status Approved for equivalence
Final Reports of the comparisons
References

CCL-K3 Technical Protocol

Measurand Angle
Transfer device 12-sided polygon and 4 angle blocks
Comparison type Key Comparison
Consultative Committee CCL (Consultative Committee for Length )
Conducted by CCL (Consultative Committee for Length )
Comments

Results published on 15 September 2008

Angle standards

Pilot institute NMISA
National Metrology Institute of South Africa
South Africa
Contact person O. Kruger

+27 12 841 4340
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
NMISA

National Metrology Institute of South Africa, South Africa, AFRIMETS

CENAM

Centro Nacional de Metrologia, Mexico, SIM

INRIM

Istituto Nazionale di Ricerca Metrologica, Italy, EURAMET

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

METAS

Federal Institute of Metrology, Switzerland, EURAMET

NIM

National Institute of Metrology, China, APMP

NIST

National Institute of Standards and Technology, United States, SIM

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NRC

National Research Council, Canada, SIM

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

SMU

Slovensky Metrologicky Ustav, Slovakia, EURAMET

VNIIM

D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET

Comparison
Comparison close

12-sided polygon

MEASURAND : Deviation from nominal angle between two faces of the polygon

For each face-to-face reading, the key comparison reference value, xR, is calculated as the weighted mean of all participants' results. Its standard uncertainty, uR, is calculated as the standard deviation of the weighted mean.

For each face-to-face reading, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in milliseconds:
Di = (xi - xR) and its expanded uncertainty Ui = 2(ui2 - uR2)1/2.

The degrees of equivalence between pair of laboratories have not been computed for this key comparison.

Angle blocks

MEASURAND : Deviation from nominal angles 5", 5', 30', and 5°

For each angle block, the key comparison reference value, xR, is calculated as the weighted mean of all participants' results. Its standard uncertainty, uR, is calculated as the standard deviation of the weighted mean.

For each angle block, the degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms, both expressed in milliseconds:
Di = (xi - xR) and its expanded uncertainty Ui = 2(ui2 - uR2)1/2.

The degrees of equivalence between pair of laboratories have not been computed for this key comparison.
Comparison
Comparison close

12-sided polygon

MEASURAND : Deviation from nominal angle between two faces of the polygon

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

* dates of measurements at the Pilot Laboratory: Jul 2000, 20 Jan 2001, 12 Dec 2001, 03 Jun 2002, and Aug 2002

Angle blocks

MEASURAND : Deviation from nominal angles 5", 5', 30', and 5°

xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi

* dates of measurements at the Pilot Laboratory: Jul 2000, 20 Jan 2001, 12 Dec 2001, 03 Jun 2002, and Aug 2002