Comparison
Comparison close

CCQM-K12 and CCQM-K12.2

MEASURAND : Mass fraction of creatinine in human serum
 

Degrees of equivalence Di and expanded uncertainty Ui (95% level of confidence) expressed in µg/g.


Red diamonds: CCQM-K12
Blue squares: CCQM-K12.2

Comparison
Comparison close

CCQM-K12 and CCQM-K12.2

MEASURAND : Mass fraction of creatinine in human serum
 

Degrees of equivalence Di and expanded uncertainty Ui (95% level of confidence) expressed in µg/g.


 

c

Information is available in Summary Results 

Comparison
Comparison close
CC comparison
Linked comparison
CCQM-K12.2
Metrology area, Sub-field Chemistry and Biology, Organics
Description Creatinine in human serum
Time of measurements 2012
Status Approved for equivalence
Final Reports of the comparisons
Measurand Mass fraction
Transfer device Frozen serum materials
Comparison type Key Comparison
Consultative Committee CCQM (Consultative Committee for Amount of Substance)
Conducted by CCQM (Consultative Committee for Amount of Substance)
Comments

This is a subsequent key comparison to CCQM-K12.

Results published on 15 June 2018

Creatinine in human serum

CCQM-K12.2 results are linked to those of CCQM-K12 for Material I

(7 µg/g to 8 µg/g)

Pilot institute NIST
National Institute of Standards and Technology
United States
Contact person M.J. Welch

+1 301 975 3100
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
NIST

National Institute of Standards and Technology, United States, SIM

CENAM

Centro Nacional de Metrologia, Mexico, SIM

HSA

Health Science Authority, Singapore, APMP

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

LNE

Laboratoire national de métrologie et d'essais, France, EURAMET

NIM

National Institute of Metrology, China, APMP

NIMT

National Institute of Metrology (Thailand), Thailand, APMP

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

UME

TÜBITAK Ulusal Metroloji Enstitüsü, Türkiye, EURAMET

VNIIM

D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET

Comparison
Comparison close

CCQM-K12 and CCQM-K12.2

MEASURAND : Mass fraction of creatinine in human serum

The key comparison reference value, xR, is calculated as the mean of the participants' results excluding IRMM: xR = 8.217 µg/g.
The expanded uncertainty of the key comparison reference value at a 95% level of confidence is: UR = 0.066 µg/g.

The degree of equivalence of each laboratory with respect to the key comparison reference value is given by a pair of terms: Di = (xi - xR) and Ui, its expanded uncertainty corresponding to a 95% level of confidence, both expressed in µg/g.

 

Linking CCQM-K12.2 to CCQM-K12

An independent key comparison reference value was assigned from the mean, standard deviation, and pooled standard uncertainty of the results reported by the three reference laboratories KRISS, NIST and PTB and the participants.

Comparison
Comparison close

CCQM-K12 and CCQM-K12.2

MEASURAND : Mass fraction of creatinine in human serum
 

xi : result of measurement carried out by laboratory i
ui
: combined standard uncertainty of xi

CCQM-K12

CCQM-K12.2

We use cookies to optimize our website. View privacy policy