Metrology area, Sub-field | Mass and related quantities, Pressure |
Description | Pressure 0.7 MPa to 7 MPa (gauge mode) |
Time of measurements | 2020 - 2022 |
Status | Measurements completed |
References | |
Measurand | Effective area of piston-cylinder units (0.7, 1, 2, 3, 4, 5, 6, 7) MPa |
Parameters | 20 °C |
Transfer device | Pressure balance (DH Instruments - Fluke): a base PG-7601, piston-cylinder assembly (PCA) and a set of mass standards. |
Comparison type | Key Comparison |
Consultative Committee | CCM (Consultative Committee for Mass and Related Quantities) |
Conducted by | CCM (Consultative Committee for Mass and Related Quantities) |
Comments | Repeat of CCM.P-K1.c. First round of measurements finnished. Second set of measurements at CENAM Mexico underway. |
Pilot institute |
CENAM
Centro Nacional de Metrologia Mexico |
Contact person | Jorge C. Torres-Guzman +52 442 2110572 |
Additional |
Pilot laboratory | |
---|---|
CENAM |
Centro Nacional de Metrologia, Mexico, SIM |
KRISS |
Korea Research Institute of Standards and Science, Korea, Republic of, APMP |
LNE |
Laboratoire national de métrologie et d'essais, France, EURAMET |
METAS |
Federal Institute of Metrology, Switzerland, EURAMET |
NIS |
National Institute for Standards, Egypt, AFRIMETS |
NIST |
National Institute of Standards and Technology, United States, SIM |
NMIJ AIST |
National Metrology Institute of Japan, Japan, APMP |
PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
VNIIM |
D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :