CCM.F-K3.a and CCM.F-K3.b

MEASURAND : Force
NOMINAL VALUE : 500 kN

 

Degrees of equivalence Di and expanded uncertainty Ui (k = 2) expressed in 10-6

 

CCM.F-K3.a

MEASURAND : Force
NOMINAL VALUE : 1 MN

 

Degrees of equivalence Di and expanded uncertainty Ui (k = 2)
expressed in 10-6

 

CCM.F-K3.a and CCM.F-K3.b

MEASURAND : Force
NOMINAL VALUE : 500 kN

 

Degrees of equivalence relative to the CCM.F-K3 reference value:

 

Results are presented under A4 printable format in Summary Results (PDF file).

CCM.F-K3.a

MEASURAND : Force
NOMINAL VALUE : 1 MN

 

Degrees of equivalence relative to the CCM.F-K3 reference value:

 

Results are presented under A4 printable format in Summary Results (PDF file).

Comparison
Comparison close
CC comparison
Linked comparison
SIM.M.F-K3.a
Metrology area, Sub-field Mass and related quantities, Force
Description High force measurements
Time of measurements 2023 - 2024
Status Measurements in progress
References

SIM.M.F-K3.a Technical Protocol

SIM.M.F-K3.a Technical Protoccol

Measurand Force
0 MN, 0.5 MN and 1 MN
Transfer device Force measurement device
Comparison type Key Comparison
Consultative Committee CCM (Consultative Committee for Mass and Related Quantities)
Conducted by SIM (Inter-American Metrology System)
Comments The technical comparison protocol has been updated to version 4.
Pilot institute INM (CO)
Instituto Nacional de Metrología de Colombia
Colombia
Contact person Juan Alberto Arias Prieto

+571-2 54 22 22
Additional
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
INM (CO)

Instituto Nacional de Metrología de Colombia, Colombia, SIM

CENAM

Centro Nacional de Metrologia, Mexico, SIM

IDIC

Instituto de Investigaciones y Control, Chile, SIM

INEN

Servicio Ecuatoriano de Normalización, Ecuador, SIM

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

INTI

Instituto Nacional de Tecnologia Industrial, Argentina, SIM

LACOMET

Laboratorio Costarricense de Metrologia, Costa Rica, SIM

NIST

National Institute of Standards and Technology, United States, SIM

CCM.F-K3.a and CCM.F-K3.b

MEASURAND : Force
NOMINAL VALUE : 500 kN

 

The key comparison reference value, xR, is calculated as the weighted mean of the corrected measurement results from CCM.F-K3.a and CCM.F-K3.b. Correlations were considered when evaluating the associated standard uncertainty, uR.

 

The degree of equivalence of each laboratory with respect to the key comparison reference reference value is given by a pair of terms, both expressed in 10-6: Di , where Di is the relative reviation of the final result from xR, and Ui, its expanded uncertainty
(k = 2).

 

CCM.F-K3.a

MEASURAND : Force
NOMINAL VALUE : 1 MN

 

The key comparison reference value, xR, is calculated as the weighted mean of the corrected measurement results from CCM.F-K3.a. Correlations were considered when evaluating the associated standard uncertainty, uR.

 

The degree of equivalence of each laboratory with respect to the key comparison reference reference value is given by a pair of terms, both expressed in 10-6: Di , where Di is the relative reviation of the final result from xR, and Ui, its expanded uncertainty
(k = 2).

 

CCM.F-K3.a and CCM.F-K3.b

MEASURAND : Force
NOMINAL VALUE : 500 kN

CCM.F-K3.a: Two force steps of 500 kN were employed.

CCM.F-K3.b: Two compression force transducers of 500 kN and one force step of 500 kN were emplyed.

Measurements were carried out from 2005 to 2011.

The measurement results for CCM.F-K3.a and CCM.F-K3.b are presented in Section 7 (pp. 6 to 17) of the CCM.F-K3 Final report.

 

CCM.F-K3.a

MEASURAND : Force
NOMINAL VALUE : 1 MN

CCM.F-K3.a: Two compression force transducers of 1 MN were employed.

 

Measurements were carried out from 2005 to 2011.

The measurement results for CCM.F-K3.a are presented in Section 7 (pp. 6 to 17) of the CCM.F-K3 Final report.