Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in (cd/V)/(cd/V).

Relative degrees of equivalence for luminous intensity
Di 
Participating institutes
Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

Degrees of equivalence represented by Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in (cd/V)/(cd/V).

LABi Di Uneg,i Upos,i
(cd/V)/(cd/V)
(cd/V)/(cd/V)
(cd/V)/(cd/V)
NMIJ 0.0047 0.0051
NIM 0.0002 0.0032
PTB -0.0004 0.0030
METAS -0.0006 0.0061
NIST 0.0006 0.0043
NMIA -0.0018 0.0029
VNIIOFI -0.0073 0.0048
IO-CSIC -0.0011 0.0061
NPL 0.0034 0.0032
NMISA -0.0093 0.0132
NRC 0.0051 0.0123
Participating institutes
CCPR-K3.2014
Comparison
Comparison close
CC comparison
Linked comparison
SIM.PR-K3
Metrology area, Sub-field Photometry and Radiometry, Photometry
Description Luminous intensity
Time of measurements 2024 - 2026
Status Protocol complete
References

Appendix B file to register operating time of lamps

Technical protocol for SIM-PR-K3

Appendix D file to registed measurement results of lamps

Measurand Luminous Intensity
Parameters CCT between 2800 K and 2900 K
Transfer device Incandescent lamps: Osram WI 41/G lamps or FEL type
Comparison type Key Comparison
Consultative Committee CCPR (Consultative Committee for Photometry and Radiometry)
Conducted by SIM (Inter-American Metrology System)
Pilot institute CENAM
Centro Nacional de Metrologia
Mexico
Contact person C. H. Matamoros-Garcìa

+52 442 211 0500
Additional
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
CENAM

Centro Nacional de Metrologia, Mexico, SIM

CMS

ITRI Center for Measurement Standards, Chinese Taipei, APMP

IBMETRO

Instituto Boliviano de Metrología, Bolivia, SIM

INACAL

National Institute for Quality, Peru, SIM

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

INTI

Instituto Nacional de Tecnologia Industrial, Argentina, SIM

KRISS

Korea Research Institute of Standards and Science, Korea, Republic of, APMP

NIMT

National Institute of Metrology (Thailand), Thailand, APMP

NIST

National Institute of Standards and Technology, United States, SIM

NRC

National Research Council, Canada, SIM

UzNIM

Uzbek National Institute of Metrology, Uzbekistan, COOMET

Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

The key comparison reference value xR and its associated standard uncertainty uR were calculated by applying a Mandel-Paule method to the participant results, those of the NMISA and LNE/LCE-Cnam excluded:

 

        xR = 86.256 cd/V     uR = 0.059 cd/V

 

The degree of equivalence of laboratory i relative to the key comparison reference value xR is given by a pair of terms, Di = (xI - xR)/xR and its expanded uncertainty Ui at a 95 % level of confidence where Ui = 2 ui, both expressed in (cd/V)/(cd/V).

Comparison
Comparison close
Results

CCPR-K3.2014

 

MEASURAND                 Luminous intensity

 

The measurement data are listed in Appendix D of the CCPR-K3.2014 Final Report.