BIPM.RI(II)-K1.Sc-47 and EUROMET.RI(II)-K2.Sc-47
MEASURAND : Equivalent activity of 47Sc
There is no graph of equivalence since no degrees of equivalence with respect to the key comparison reference value could be computed.
BIPM.RI(II)-K1.Sc-47 and EUROMET.RI(II)-K2.Sc-47
MEASURAND : Equivalent activity of 47Sc
Lab i | Di | Ui |
/ MBq | / MBq | |
IRMM | - | - |
BNM-LNHB | - | - |
NPL | - | - |
In blue: participants in EUROMET.RI(II)-K2.Sc-47 only.
The full table of pair-wise degrees of equivalence is available in Summary Results (summary of the results as a .PDF file).
Metrology area, Sub-field | Ionizing Radiation, Section II (Measurement of Radionuclides) |
Description | Activity of radionuclide Sc-47 |
Time of measurements | 1983 |
Status | Approved for equivalence |
Final Reports of the comparisons | |
Measurand | Activity par unit mass |
Comparison type | Key Comparison |
Consultative Committee | CCRI (Consultative Committee for Ionizing Radiation) |
Conducted by | EURAMET (European Association of National Metrology Institutes) |
Comments | EUROMET.RI(II)-K2.Sc-47 results are linked to those of BIPM.RI(II)-K1.Sc-47 BIPM.RI(II)-K1.Sc-47 and EUROMET.RI(II)-K2.Sc-47 results were published on 16 December 2003. SIR equivalent activity of the radionuclide 47Sc |
Pilot institute |
IGM
Inspection Générale de la Métrologie Belgium |
Contact person | D.F.G. Reher +32 (0) 14 571 263 |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
BIPM.RI(II)-K1.Sc-47 and EUROMET.RI(II)-K2.Sc-47
MEASURAND : Equivalent activity of 47Sc
• Key comparison BIPM.RI(II)-K1.Sc-47
Key comparison reference value: there is currently no key comparison reference value for this radionuclide. |
• Linking EUROMET.RI(II)-K2.Sc-47 to BIPM.RI(II)-K1.Sc-47
The value xi is the equivalent activity for laboratory i participant in EUROMET.RI(II)-K2.Sc-47 having been normalized to the value of the IRMM as the linking laboratory (see Final Report). |
There are no degrees of equivalence with respect to the key comparison reference value. |
The degree of equivalence between two laboratories i and j, one participant in BIPM.RI(II)-K1.Sc-47 and one in EUROMET.RI(II)-K2.Sc-47, or both participants in EUROMET.RI(II)-K2.Sc-47, is given by a pair of terms expressed in MBq: Dij = xi - xj and Uij, its expanded uncertainty (k = 2), approximated by Uij = 2(ui2 + uj2 - 2ful2)1/2 with l being the linking laboratory when each laboratory is from the EUROMET and f is the correlation coefficient. |
BIPM.RI(II)-K1.Sc-47 and EUROMET.RI(II)-K2.Sc-47
MEASURAND : Equivalent activity of 47Sc
• Key comparison BIPM.RI(II)-K1.Sc-47
xi : result of measurement carried out in the SIR for the sample submitted by laboratory i
ui : combined standard uncertainty of xi
Lab i | xi / kBq |
ui / kBq |
Date of measurement |
IRMM | 164590 | 340 | 83-10-14 |
• Key comparison EUROMET.RI(II)-K2.Sc-47
xi : result of measurement carried out at laboratory i converted to the equivalent activity through the IRMM
ui : combined standard uncertainty of xi
Lab i | xi / kBq |
ui / kBq |
Measurement report date |
BNM-LNHB | 164840 | 270 | 1983 |
NPL |
164980 |
340 |
1983 |