Comparison
Comparison close
Results

BIPM.RI(II)-K1.Mn-54

MEASURAND   Equivalent activity of 54Mn

 

Degrees of equivalence represented by Di = (xI - xR) and Ui, its expanded uncertainty (k = 2) both expressed in MBq.

Equivalent activity of 54Mn
Di / MBq
Participating institutes
Comparison
Comparison close
Results

BIPM.RI(II)-K1.Mn-54

MEASURAND   Equivalent activity of 54Mn

 

Degrees of equivalence represented by Di = (xI - xR) and Ui, its expanded uncertainty (k = 2) both expressed in MBq.

LABi Di Uneg,i Upos,i
MBq
MBq
MBq
NPL 0.02 0.11
BKFH -0.11 0.13
LNE-LNHB -0.05 0.10
PTB 0.00 0.12
POLATOM 0.27 0.29
Participating institutes
BIPM.RI(II)-K1.Mn-54
Comparison
Comparison close
BIPM comparison
Linked comparison
BIPM.RI(II)-K1.Mn-54
Metrology area, Sub-field Ionizing Radiation, Section II (Measurement of Radionuclides)
Description Activity of radionuclide Mn-54
Time of measurements 1975 -
Status Continuous, approved for equivalence
Final Reports of the comparisons
Measurand SIR equivalent activity
Transfer device Radioactive solution
Comparison type Key Comparison
Consultative Committee CCRI (Consultative Committee for Ionizing Radiation)
Conducted by BIPM (Bureau International des Poids et Mesures)
Comments SIR: Système International de Référence, International Reference System
Pilot institute BIPM
Bureau International des Poids et Mesures
BIPM - International Organization
Contact person Carine Michotte

+33 (0) 1 45 07 70 85
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
BIPM

Bureau International des Poids et Mesures, BIPM - International Organization, N/A

ANSTO

Australian Nuclear Science and Technology Organisation, Australia, APMP

BARC

Bhabha Atomic Research Centre, India, APMP

BEV

Bundesamt für Eich- und Vermessungswesen, Austria, EURAMET

BFKH

Government Office of the Capital City Budapest, Hungary, EURAMET

Magyar Kereskedelmi Engedélyezési Hivatal (MKEH), now BFKH

Magyar Kereskedelmi Engedélyezési Hivatal (MKEH), now BFKH

CMI

Czech Metrology Institute, Czechia, EURAMET

Czech Metrologiacl institute, Inspectorate for Ionizing radiation (CMI/IIR), now CMI

IAEA

International Atomic Energy Agency, IAEA - International Organization, SIM

IRA

Institut Universitaire de Radiophysique Appliquée, Switzerland, EURAMET

LNE-LNHB

Commissariat à l'énergie atomique / Laboratoire National Henri Becquerel, France, EURAMET

LNMRI/IRD

Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, IRD, Brazil, SIM

NIST

National Institute of Standards and Technology, United States, SIM

NMIJ AIST

National Metrology Institute of Japan, Japan, APMP

NPL

National Physical Laboratory, United Kingdom, EURAMET

Measurements complete

POLATOM

Radioisotope Centre Polatom, Poland, EURAMET

Report in progress, draft A

PTB

Physikalisch-Technische Bundesanstalt, Germany, EURAMET

-

Comparison
Comparison close
Results

BIPM.RI(II)-K1.Mn-54

MEASURAND   Equivalent activity of 54Mn

 

Key comparison reference value: the SIR reference value for this radionuclide is  xR  = 19 246 kBq with a standard uncertainty, uR = 19 kBq (see Section 4.1 of the Final Report).

The value xi is the equivalent activity for laboratory i.

 

The degree of equivalence of each laboratory with respect to the key comparison reference value is given by a pair of terms:

Di = (xi - xR) and Ui, its expanded uncertainty  (k = 2), both expressed in MBq, and

Ui = 2((1 - 2wi)ui2 + uR2)1/2 , where wi is the weight of laboratory i contributing to the calculation of xR.

Comparison
Comparison close
Results

BIPM.RI(II)-K1.Mn-54

MEASURAND   Equivalent activity of 54Mn

 

xi   result of measurement carried out in the SIR for the sample submittedby laboratory iLabi

ui   combined standard uncertainty of xi

 

  Labi xi ui Date of measurement
  / kBq / kBq
  NPL 19 268 55 2006-03-09
  BKFH 19 139 66 2006-06-22
  LNE-LNHB 19 199 54 2006-07-19
  PTB 19 250 61 2017-09-13
  POLATOM 19 520 140 2024-04-19