Metrology area, Sub-field | Electricity and Magnetism, High voltage and current |
Description | Lightning impulse voltage measurement systems |
Time of measurements | 2016 - 2019 |
Status | Approved |
Final Reports of the comparisons | |
References | |
Measurand | Lightning impulse epoch 0.84/50 µs and 1.56/50 μs. Lightning impulse voltage peak value -100 kV, -200 kV, -300 kV, -400 kV, -500 kV, -600 kV, -700 kV and +700 kV. Linear extension in 500 kV steps up to 2 MV. |
Parameters | T = [16;26] °C, RH = [40;50] % |
Transfer device | Reference measurement system provided by HIGHVOLT. It contains a resistive measuring divider SMR 10/700 (for up to 700kV LI), a cable and a digital recorder MIAS 200-2/2C (200MS/s, 12bit, 2 channels). Impulse voltage calibrator and chopping gap. |
Comparison type | Supplementary Comparison |
Consultative Committee | CCEM (Consultative Committee for Electricity and Magnetism) |
Conducted by | EURAMET (European Association of National Metrology Institutes) |
RMO Internal Identifier | EURAMET 1391 |
Comments | |
Pilot institute |
SP
Technical Research Institute of Sweden from 2017 Research Institutes of Sweden AB Sweden |
Contact person | A-P Elg +46 10 516 57 34 |
Pilot laboratory | |
---|---|
SP |
Technical Research Institute of Sweden from 2017 Research Institutes of Sweden AB, Sweden, EURAMET |
INTI |
Instituto Nacional de Tecnologia Industrial, Argentina, SIM |
LCOE |
Laboratorio Central Oficial de Electrotecnica, Spain, EURAMET |
LNE |
Laboratoire national de métrologie et d'essais, France, EURAMET |
MIKES |
VTT Technical Research Centre of Finland Ltd, Centre for Metrology/Mittatekniikan keskus, Finland, EURAMET |
NMIA |
National Measurement Institute, Australia, Australia, APMP |
NRC |
National Research Council, Canada, SIM |
PTB |
Physikalisch-Technische Bundesanstalt, Germany, EURAMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :