CCQM-K48.2014
MEASURAND : Amount content of chloride in potassium chloride
NOMINAL VALUE : 13.4 mol/kg
Degrees of equivalence, Di and expanded uncertainty Ui (k = 2), expressed in relative terms
CCQM-K48.2014
MEASURAND : Amount content of chloride in potassium chloride
NOMINAL VALUE : 13.4 mol/kg
Degrees of equivalence, Di and expanded uncertainty Ui (k = 2), expressed in relative terms
Results are presented under A4 printable format in Summary Results (PDF file).
Metrology area, Sub-field | Chemistry and Biology, Electrochemistry |
Description | Chloride in KCl |
Time of measurements | 2014 |
Status | Approved for equivalence |
Final Reports of the comparisons | |
Measurand | Amount content of chloride in KCl |
Transfer device | Dedicated samples |
Comparison type | Key Comparison |
Consultative Committee | CCQM (Consultative Committee for Amount of Substance) |
Conducted by | CCQM (Consultative Committee for Amount of Substance) |
Comments | CCQM-K48.2014, Chloride in KCl, is a repeat of CCQM-K48. In was originally registered as CCQM-K114. Results published on 1 September 2016 Assay of potassium chloride
|
Pilot institute |
NIM
National Institute of Metrology China |
Contact person | MA LIANDI +86 10 642 23 987 |
Pilot laboratory | |
---|---|
NIM |
National Institute of Metrology, China, APMP |
CENAM |
Centro Nacional de Metrologia, Mexico, SIM |
GUM |
Glowny Urzad Miar, Central Office of Measures, Poland, EURAMET |
INMETRO |
Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM |
KRISS |
Korea Research Institute of Standards and Science, Korea, Republic of, APMP |
NIST |
National Institute of Standards and Technology, United States, SIM |
NMIJ AIST |
National Metrology Institute of Japan, Japan, APMP |
SMU |
Slovensky Metrologicky Ustav, Slovakia, EURAMET |
UNIIM |
Ural Scientific and Research Institute for Metrology, Rosstandart, Russian Federation, COOMET |
VNIIFTRI |
Institute of Physical Technical and Radiotechnical Measurements, Rosstandart, Russian Federation, COOMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
CCQM-K48.2014
MEASURAND : Amount content of chloride in potassium chloride
NOMINAL VALUE : 13.4 mol/kg
The key comparison reference value, xR, is calculated as the median of all participant results, and its standard uncertainty, uR, is calculated as 1.858*[median(xi-xR)]*(n-1)-1/2 , where n represents the total number of participants and xi is the result of participant i. |
xR = 13.41311 mol/kg and uR = 0.00083 mol/kg
The degree of equivalence of laboratory i with respect to the key comparison reference value is given by a pair of terms: Di = (xi - xR)/xR and Ui, its expanded uncertainty (k = 2), Ui = [2(ui2 + uR2)1/2]/xR, both expressed in relative terms. |
CCQM-K48.2014
MEASURAND : Amount content of chloride in potassium chloride
NOMINAL VALUE : 13.4 mol/kg
xi : result of measurement carried out by laboratory i
ui : combined standard uncertainty of xi