MEASURAND Amount fraction ammonia in nitrogen
Degrees of equivalence represented by Di = (xI - xRi) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in µmol/mol.
MEASURAND Amount fraction ammonia in nitrogen
Degrees of equivalence represented by Di = (xI - xRi) and its expanded uncertainty Ui at a 95 % level of confidence, both expressed in µmol/mol.
LABi | Di | Uneg,i | Upos,i | |
---|---|---|---|---|
µmol/mol |
µmol/mol |
µmol/mol |
||
NIST | -0.103 | 0.204 | ||
CERI | 0.046 | 0.185 | ||
NPL | 0.018 | 0.402 | ||
KRISS | 0.056 | 0.146 | ||
NIM | 0.238 | 0.223 | ||
VSL | -0.030 | 0.127 | ||
METAS | -0.681 | 0.180 | ||
VNIIM | 0.586 | 0.251 |
Metrology area, Sub-field | Chemistry and Biology, Gases |
Description | NH3 in Nitrogen |
Time of measurements | 2017 |
Status | Approved for equivalence |
Final Reports of the comparisons | |
Measurand | Amount fraction Ammonia |
Transfer device | Dedicated samples |
Comparison type | Key Comparison |
Consultative Committee | CCQM (Consultative Committee for Amount of Substance) |
Conducted by | CCQM (Consultative Committee for Amount of Substance) |
Pilot institute |
VSL
VSL Netherlands |
Contact person | A. van der Veen +31 15 2691500 |
Pilot laboratory | |
---|---|
VSL |
VSL, Netherlands, EURAMET |
CERI |
Chemicals Evaluation and Research Institute, Japan, APMP |
KRISS |
Korea Research Institute of Standards and Science, Korea, Republic of, APMP |
METAS |
Federal Institute of Metrology, Switzerland, EURAMET |
NIM |
National Institute of Metrology, China, APMP |
NIST |
National Institute of Standards and Technology, United States, SIM |
NPL |
National Physical Laboratory, United Kingdom, EURAMET |
VNIIM |
D.I. Mendeleyev Institute for Metrology, Rosstandart, Russian Federation, COOMET |
This page proposes print-out on A4 paper (portrait) of the comparison details (best printed out using a black and white printer).
Please, select items to be printed out, then click on "OK" :
MEASURAND Amount fraction ammonia in nitrogen
The key comparison reference value xRi and its associated standard uncertainty uRi are computed for each cylinder as explained in the CCQM-K117 Final Report.
Labi | xR,i | u Ri |
µmol/mol | µmol/mol | |
NIST | 13.743 | 0.056 |
CERI | 13.814 | 0.056 |
NPL | 13.782 | 0.058 |
KRISS | 13.514 | 0.053 |
NIM | 13.612 | 0.057 |
VSL | 14.310 | 0.052 |
METAS | 13.621 | 0.065 |
VNIIM | 13.824 | 0.056 |
The degree of equivalence of laboratory i relative to the key comparison reference value xRi is given by a pair of terms, both expressed in mol/mol:
Di = (xi - xRi) and its expanded uncertainty Ui at a 95 % level of confidence where Ui = 2 ui.
MEASURAND Amount fraction ammonia in nitrogen
xi measured mass fraction reported by laboratory i, Labi
ui combined standard uncertainty of xi
Labi | xi | ui |
µmol/mol | µmol/mol | |
NIST | 13.640 | 0.100 |
CERI | 13.860 | 0.090 |
NPL | 13.800 | 0.200 |
KRISS | 13.570 | 0.075 |
NIM | 13.850 | 0.100 |
VSL | 14.280 | 0.070 |
METAS | 12.940 | 0.065 |
VNIIM | 14.410 | 0.115 |