Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

Degrees of equivalence represented by D and its expanded uncertainty Ui  (k = 2), both expressed in mg.

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

Degrees of equivalence represented by Di  and its expanded uncertainty Ui  (k =2), both expressed in mg.

 

 

 

 

SIM.M.M-K4
Metrology area, Sub-field Mass and related quantities, Mass Standards
Description Comparison of mass standards
Time of measurements 2009 - 2013
Status Approved for equivalence
Final Reports of the comparisons
Measurand Mass: 1 kg
Transfer device A 1 kg stainless steel standard
Comparison type Key Comparison
Consultative Committee CCM (Consultative Committee for Mass and Related Quantities)
Conducted by SIM (Inter-American Metrology System)
Comments

This comparison was originally labelled SIM.M.M-K1 but was renamed SIM.M.M-K4 on 29 March 2016 as to be linked to the CCM.M-K4 comparison

Results published on 26 April 2016

SIM.M.M-K4 and APMP.M.M-K4.1 results are linked to CCM.M-K4 results.

Stainless steel 1 kg standards

Pilot institute INTI
Instituto Nacional de Tecnologia Industrial
Argentina
Contact person Fernando KORNBLIT

+54 11 4724 5402
First Name Last Name
wwww@ww.www +356719836 Institute 1 Institute 1 Khmelnitskiy
Pilot laboratory
INTI

Instituto Nacional de Tecnologia Industrial, Argentina, SIM

CENAM

Centro Nacional de Metrologia, Mexico, SIM

CESMEC

Centro de Estudios, Medición y Certificación de Calidad, Chile, SIM

INMETRO

Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brazil, SIM

LACOMET

Laboratorio Costarricense de Metrologia, Costa Rica, SIM

LATU

Laboratorio Tecnologico del Uruguay, Uruguay, SIM

NRC

National Research Council, Canada, SIM

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

CCM.M-K4

For each of the travelling mass standards, the key comparison reference value, xR, and its standard uncertainty, uR, were obtained using the generalized linear least-squares method as explained in section VII of the CCM.M-K4 Final Report.

The degree of equivalence of each laboratory i with respect to the reference value is given by a pair of terms:

Di and Ui its expanded uncertainty (k = 2), both expressed in mg.
Detailed information on the evaluation of Di and Ui may be found in section VIII of the Final Report.

There were no degrees of equivalence between pair of laboratories calculated for this comparison.

 

Linking SIM.M.M-K4 to CCM.M-K4

The results of the SIM.M.M-K4 comparison were linked to CCM.M-K4 via the CENAM and NRC. The linking procedure is described on pages 5 to 7 of the SIM.M.M-K4 Final Report.

 

Linking APMP.M.M-K4.1 to CCM.M-K4

KRISS participated in both key comparisons, APMP.M.M-K4.1 and CCM.M-K4, providing a link between the NMC, A*STAR result and the key comparison reference value of CCM.M-K4. The linkage process is described in Section 7 of the APMP.M.M-K4.1 Final Report.

 

Linking EURAMET.M.M-K4.2015 to CCM.M-K4

The results of the EURAMET.M.M-K4.2015 comparison were linked to CCM.M-K4 via the BEV, BIPM, LNE, METAS and NPL. The linkage process is described in Section 7 of the EURAMET.M.M-K4.2015 Final Report.

 

Linking GULFMET.M.M-K4 to CCM.M-K4

The results of the GULFMET.M.M-K4 comparison were linked to CCM.M-K4 via the INRIM, METAS and KRISS. The linkage process is described in Section 7 of the GULFMET.M.M-K4 Final Report.

Comparison
Comparison close

CCM.M-K4, SIM.M.M-K4, APMP.M.M-K4.1, EURAMET.M.M-4.2015 and GULFMET.M.M-K4

MEASURAND : Mass
NOMINAL VALUE: 1 kg

 

CCM.M-K4

The key comparison was organized in four simultaneous “petals”. Each of the four participants within a petal received the same two travelling mass standards as follows:
Petal 1: Mass standards B5 and C1; Petal 2: Mass standards B6 and C2; Petal 3: Mass standards B7 and D1; Petal 4: Mass standards B8 and D2.

The pilot laboratory, the BIPM, carried out a comparison of the standards before the comparison started, and after completion of measurements within each petal.

xi : reported result obtained as the difference between the measurement of the mass standard carried out by laboratory i and its nominal value, and corrected for the drift of the travelling mass standard as explained on page 8 of the Final Report.
ui : combined standard uncertainty of xi

 

SIM.M.M-K4

The laboratory individual measurement results are given on page 3 of the SIM.M.M-K4 Final Report.

 

APMP.M.M-K4.1

The results reported by the particpants in APMP.M.M-K4.1 are given in section 6 of the APMP.M.M-K4.1 Final Report.

 

EURAMET.M.M-K4.2015

The results reported by the particpants in EURAMET.M.M-K4.2015 are given in Table 5 of the EURAMET.M.M-K4.2015 Final Report.

 

GULMET.M.M-K4

The results reported by the particpants in GULFMET.M.M-K4 are given in Table 5 of the GULFMET.M.M-K4 Final Report.